Courier XMF emulator harness

The I-modem's AT interface answers. isdn-run now models the 386EX SIO's receive side - RBR, IIR, MSR and the IRQ3 line its own ISR at 0xb2aa2 names - so commands can be typed at the firmware and its replies read back: --send ATI3 returns USRobotics Courier I-Modem with ISDN/V.34, and --terminal attaches a live console. For normal interactive use, run:

./courier isdn-run Ie030002.nac --terminal

Type AT commands normally and press Return; press Ctrl-] to exit. Terminal mode runs until detached and does not print the diagnostic JSON report unless --report is also supplied. During interaction the guest clock is paced to the timer model's 5 million instructions per second, so the modem continues running without racing hours ahead of the terminal. See the AT interface for the ATI0-ATI30 sweep, and I-modem terminal framing for how the external board's attention receiver makes consecutive AT commands independent.

The captured 20.16 MHz DSP boot ROM is now integrated for the 302/403 firmware under --with-dsp. The DSP executes reset and downloads its resident through the ROM loader, with corrected PMST vector decoding and IDLE wakeup. See boot-ROM integration.

The DSP 3.1.2 audio trace now runs the original tone selector, oscillator, mixer and serial ISR to produce all 16 DTMF pairs. It fixes square, product-load and normalization instruction errors that silenced this path, and emits a listenable WAV. This board image has a DRR/DXR sample-buffer path, and it drives the codec itself: the ISR implements the AC0x secondary-frame protocol and reset programs six of the part's control registers, so claims below based on main211 do not describe it. Its 7200 Hz is the dial path's rate, not the board's; the PCM modulations it advertises force a rate change - and it makes one: a six-row table selects 7200, 7578.95 or 8000 Hz from V.34's negotiated symbol rate. See the codec sample rates, and the codec rate for how the question stood before.

The DSP 3.1.2 hardware comparison records a fresh connected-board mailbox sequence and its replay through the original DSP dispatcher and sender. It identifies the current firmware's tone selector, demonstrates the acknowledgement behavior needed to receive replies, and keeps the remaining sample-dependent reply mismatch explicit. Older mailbox no-op and stream assumptions must not be applied to this firmware unchanged.

This repository contains a reproducible dual-core firmware harness for main211.xmf. It validates and splits the update image, executes the Intel 80186 supervisor in a 1 MiB instrumented address space, and runs the recovered TMS320C51 program with a standalone 16-bit fixed-point DSP core.

For the older SV25.XMD, ./courier recovery-run SV25.XMD runs a separate, read-only 80188 recovery-loader harness from flash 0x7dbc0 to the complete SDL Xmodem prompt. It reports every setup write, mapping observation, serial byte and stop condition as JSON. See SV25 recovery harness for the recovered XMD block decode, memory map, peripheral assumptions and tests. The DSP ROM-read diagnostic provides a C5x kernel and a RAM supervisor launcher for the 20.16 MHz reference. Its offline test executes reset/download, DSP mailbox output and supervisor serial readback. Hardware handshakes remain modeled; a physical RAM-load and launch mechanism is still unverified. The same document describes the read-only ATGLK2 serial collector for the user's 20.16 MHz, 512 KiB modem. That board now runs supervisor 7.4.16 / DSP 3.1.2 - the image under artifacts/courier-board-21210-capture-403/ - having previously reported 7.3.14 / DSP 3.0.13, which is what the older notes below describe:

.venv/bin/python -m courier_emu.flash_dump \
  --device /dev/cu.usbserial-21210 --baud 115200 \
  --output artifacts/courier-board-capture

It requires a new output directory, checks the modem identity and known reset vector, and verifies two matching reads of every 256-byte page before publishing a complete image. Raw replies and partial blocks are retained. This captures CPU-visible flash; DSP internal ROM requires a separate experiment.

The hardware tick, the audio path, and the DSP's low program memory settles three things the harness had been carrying as assumptions, each from more than one source. One firmware tick is 5.000 ms: the board measures 1.000031 seconds per S18 unit over twelve &T1 runs, both builds convert S-register seconds to ticks by multiplying by 200, and both program 80186 Timer 0 for exactly 5 ms on their own crystal - 0x6270 at 20.16 MHz and 0x7e00 at 25.8048 MHz, which also identifies main211 as the 25.8048 MHz build. A port sweep during AT&T8 analogue loopback shows no CPU port carrying samples, so the 80186 is not in the audio path; where it goes on the DSP side is still open, and an earlier claim here that it arrives on the C5x serial port is withdrawn — at run time the DSP polls DRR, TRCV and the ASIC's own ports together, and never transmits on either serial port after reset. And the C51's mask ROM is not what the modem executes - the firmware supplies program words 0000..75d9, including the reset code, and programs external-memory wait states — and the supervisor's own download stream, which the bridge checks rather than assumes, matches that segment byte for byte (bootstrap_match, 60,344 bytes), so those words are RAM the CPU writes.

What is actually on the board identifies the parts from a photograph, each checked against the firmware where it can be. The large NEC package is 1-016-905 — a USR part number on an NEC-fabricated gate array — and it is the "interposed ASIC" these notes model as a black box: the mailbox, the DSP download window, the codec bring-up, the line detector and the missing tone generator are all in that one package. The 40.320 MHz oscillator also confirms CLKOUT is 20.16 MHz, which is the last thing the tick derivation needed.

Modelling the 20.16 MHz ASIC reads that gate array's port space off the running board with python -m courier_emu.asic_probe, which writes nothing. Only even addresses are decoded, the decode stops at 0x7f (above it the bus just returns the address), and the idle default is 0x00 - where the harness returns 0xff for any port it does not model. The measured map is courier_emu.asic_ports; it is published rather than wired in, and it does not fix the ROM transmit bug.

The constants that rested on the old calibration have been moved with it: INSTRUCTIONS_PER_MS 1,111 -> 4,348, SUGGESTED_TICK_MS 10 -> 5, and RING_START_MS 8,000 -> 2,000 ms so the first ring keeps its old instruction offset. At equal line time the linked pair's receive backlog falls from 4.88x to 1.25x, codec_rx_consumed from 66,267 to 271,475, and both sides still reach CONNECT. Runs now cover about four times less line time per instruction, so link needs roughly 156M instructions to see what 40M used to.

The boot-block flash loader documents the downloader FreeLSD and SDL.EXE talk to, and python -m courier_emu.sdl_download implements the host side for a raw 512 KiB image. Building and checking a record stream is offline; the report gives the CRC to hand the modem, the blocks the download erases, the two parameter blocks it never erases, and the result of replaying the stream through a model of the loader's own state machine. The wire exchange is transcribed from the disassembly and has not been run against hardware, and the loader is only reachable after a reset that fails the flash CRC or matches the bootstrap DIP-switch combination.

For live CPU RAM, use python -m courier_emu.ram_dump with the same options and a new output directory. It preserves two passes through 00000..0feff, skips the peripheral registers at 0ff00..0ffff, reports changing bytes, and extracts the known EEPROM settings cache. See the same diagnostic document for the snapshot limitations and cached-settings layout. Add --window upper to investigate CPU addresses 10000..1ffff instead; that mode also takes six bracketed comparisons with lower RAM to check for possible mirroring, without writing test patterns.

Recovered main211.xmf layout

File range Contents
0x00000..0x001ff 512-byte product text header
0x00200..0x1b5df 55,792 little-endian TMS320C51 words
0x1b5e0..0xb7fff Intel 80186 supervisor plus erased flash padding

The image is mapped at physical 0x40000. The normal supervisor initializer is 5b5e:0410 (physical 0x5b9f0). The six bytes at 5b5e:0000 are instead a fatal-error entry: they select error 0x0b and jump to the LED blinker at physical 0x5c74a. The CPU's immutable reset vector is not present in this update payload, so the harness starts at the recovered supervisor initializer.

The DSP area is a segmented program image rather than one flat load:

File range C51 program words Role
0x002f0..0x0eea3 0000..75d9 reset and boot block
0x0eea4..0x101ff de83..e830 service overlay; entry at de89
0x10200..0x1b5df 8000..d9ef resident high bank

Usage

Everything runs through the ./courier launcher. There is nothing to install and no environment to activate: on first use it creates .venv beside the repository, installs the project into it, and from then on just starts the CLI.

./courier info main211.xmf
./courier extract main211.xmf extracted/main211

CPU execution is selectable. The non-JIT interpreter uses a guarded native execution loop with Python fallback, with an 80186EB profile for analog Courier images and a 386EX profile for I-Modem images:

./courier run main211.xmf --cpu-engine interpreter --instructions 1000 --summary
./courier isdn-run Ie030002.nac --cpu-engine interpreter --instructions 10000 --report

The interpreter shares the existing peripheral, interrupt, flash and I/O models and requires no executable-memory/JIT permission. Native execution falls back at device accesses, watched addresses and instructions outside its supported subset. The Python reference still determines instruction coverage; unsupported instructions stop with their opcode, profile and physical address. ISDN per-address profiling is enabled by --report; ordinary runs use bounded instruction-clock callbacks instead. COURIER_X86_NATIVE=0 selects the Python reference for comparison.

Measure firmware execution with python tools/benchmark_x86.py Ie030002.nac or python tools/benchmark_x86.py IDSDL302.ROM --with-dsp. Add --profile-exits to identify native fallback addresses (with profiling overhead), or --python for the reference engine. See interpreter performance for measured workloads and remaining limits.

It uses uv when that is on PATH and falls back to venv plus pip otherwise. PYTHON=<interpreter> chooses the interpreter it builds the environment from (3.10 or later), COURIER_EMU_VENV=<path> moves the environment, and make clean-venv discards it. ./courier may be run from any directory. If you would rather manage the environment yourself, install the project with pip install -e '.[execute,disasm]' and use python3 -m courier_emu in place of ./courier everywhere below.

Execution uses Unicorn's 16-bit x86 core and runs in an isolated child process:

./courier run main211.xmf --instructions 250000
./courier run main211.xmf --instructions 1000000 --summary
./courier run main211.xmf --instructions 7000000 --with-dsp --at AT --summary

The DSP defaults to C51 for Courier. Select --model c53 for a C53 image; raw MICA harnesses can use NativeC5x.from_program(..., model="c53"). See DSP memory models for on-chip maps and GREG board configuration.

The C5x runner has no third-party runtime dependency; it builds with the system C++17 compiler on first use:

./courier dsp-run main211.xmf
./courier dsp-run main211.xmf --trace 40
./courier dsp-run main211.xmf --port 0x50=0x1234

With no supervisor or line-side events injected, main211.xmf reaches a deterministic 169-address service/polling cycle after 10,241 DSP instructions and reports status: stable-loop. Use --instructions to extend the run or --trace-start with --trace to inspect a later instruction window. Opcode forms not exercised by this firmware path fail explicitly with their PC instead of silently producing guessed state.

The known fatal-blinker calibration loop, initial 80186 timer-ready poll, and firmware tick-delay helpers are accelerated by default because a CPU-only core cannot supply their hardware timing. Use --real-delays when instruction-accurate delay counts matter.

Seed hardware input values with repeatable --port PORT=VALUE arguments. Port 0x40 is the first recovered board-control latch. The recovered DTE UART model accepts --at COMMAND (which appends carriage return) or literal --serial-input TEXT. Its RX ISR is vector 0x0e, with status/control at port 0x00, data at port 0x0a, and RX-ready bit 0x08. serial_text, serial_interrupts, and serial_trace report the resulting terminal exchange. The modeled DTE attention detector accepts the firmware's all-uppercase or all-lowercase AT prefix and passes only the remaining command body to the banked parser. Captured output is capped at 64 KiB; serial_truncated reports when a diagnostic command exceeds that limit.

A command line is offered to the firmware only from its command-line-ready state. The state machine publishes that as the callback pointer at 0x02ac: a8d9 collects a line a character at a time, the terminator advances it to a910, which parses the line and prints the result, and the end-of-command path at a8b1 clears the collector and returns to a8d9. Bytes delivered into the a910 window are assembled into a buffer nothing goes on to parse - the firmware's own type-ahead flag at 0x1cf2 is what would carry a line across, and it is set by the DTE front-end this harness stands in for. So the harness waits for a8d9 and re-arms the collect flag at 0x1cee bit 0x40 for each line, exactly as it does once at the main-loop milestone. That is what makes a second and third command answer.

The parameter flash, and storing a profile

AT&W writes the working profile to the parameter store. That store is four 4 KiB sectors at physical 0xf8000, each ending in a 32-bit version at 0xffa and a CRC-16/CCITT at 0xffe; the search at 0x7e07c checksums all four and keeps the highest version that verifies. parameters.py documents the layout, and the parameters subcommand builds a sector.

The writer at 0x7dfa8 does not touch the part directly. It calls the boot block through int 0x0a with an ASCII service letter in BL:

service meaning
E (0x45) erase the 4 KiB sector selected by ES
W (0x57) program the word in AX at ES:DI, then advance DI
S (0x53) firmware-update path, not modelled
L (0x4c) block lock/select, not modelled

An XMF update image carries the application only, so in a run built from one that vector points at nothing and AT&W stops on the first call. E and W are answered by the harness when a part is attached, which is what AT&W needs and no more; S and L still stop the run rather than continue on a guess.

./courier run main211.xmf --parameter-flash board.flash --at ATS0=7 --at 'AT&W'
./courier run main211.xmf --parameter-flash board.flash --at 'ATS0?'

The second run answers 007. The file is created erased (0xff, which is what the blank check at 0x7e0e3 scans for), a 4 KiB file is accepted as the first sector, and the run reports a flash block with the erase and program counts and each sector's version and checksum validity. Storing repeatedly walks the sectors in turn and erases one to wrap, all driven by the firmware's own writer. refused_bits counts bits a program would have had to set rather than clear: it stays zero while the model and the firmware agree about what an erase leaves behind.

With a stored profile attached, ATI5 renders it rather than the empty-store page.

The time base, and what waits on it

The supervisor arms countdowns and waits on them - ATI11 gives itself 20 ticks at 0x62d68 before printing an empty diagnostics page. Nothing drives them: the chain that decrements them is entered on vector 0x0f, which this firmware keeps masked for the whole run, so ATI10 and ATI11 stop partway and every other firmware timeout waits forever.

--tick-ms MS exists to experiment with that edge, but it honours the mask, so today it delivers nothing and the ticks count stays zero. That is deliberate: an edge the firmware has switched off is one the board cannot take.

--tick-source dsp is the other candidate, and it is the one worth running. It paces the chain off the DSP frame interrupt instead of off a period, which is the only arrangement that leaves both of the firmware's mutual watchdogs quiet - they bound the legal ratio to between 1/25 and 3 ticks per frame, and 1:1 sits inside it. It is still off by default, because 1:1 within that band is a choice rather than a measurement. With it the diagnostics pages finish, the line-detector poller runs, and the harness stops forging the two counters that poller feeds; see "Two instances on one line" for what a linked pair does then. courier_firmware_analysis.md has the evidence.

Talking to it while it runs

--at queues commands before boot. --console instead attaches this terminal to the DTE port for as long as the run lasts: type commands, watch the modem answer, Ctrl-] to detach. --instructions then defaults to effectively unbounded, so the session ends when you do.

./courier run main211.xmf --console
./courier run main211.xmf --console --daa-line dial-tone --nvram board.eeprom

Everything the modem sends goes to stdout and the run's own report goes to stderr, so --console > session.txt captures exactly what the firmware said. Input may also be piped, which is the same live path without a terminal:

printf 'ATI3\rATI4\r' | ./courier run main211.xmf --console --instructions 9000000

--serial-pty exposes the same port as a pty device instead of attaching this terminal, for anything that drives a serial modem:

./courier run main211.xmf --serial-pty
# serial console on /dev/ttys002
screen /dev/ttys002

Both report a console block counting the bytes each way, what a terminal that stopped reading dropped, and whether the far end closed. Typed bytes are polled every 8,192 instructions - about a hundred times a second at the speed this core runs, which is roughly the real board's.

Transmit bytes come from the 80186 integrated-UART feed. The routine at 5b5e:184b loads the byte in AL, waits for transmit status bit 0x08 at 0xff66, then applies the framing transform at 5b5e:1913 and writes the result to 0xff6a. Both of its wait edges (5b5e:1874 and 5b5e:1884) branch back to the routine's own entry rather than looping in place, so a byte crosses 0x5ce2b once per spin but is accepted only once, at 0x5ce66. Two things follow, and both are modeled:

  • A CPU-only core never drains the transmit-holding register, so status bit 0x08 stays clear and the routine spins forever. The modeled DTE reports itself ready at the wait point. This is a missing device rather than a calibrated delay, so it applies regardless of --real-delays.
  • 5b5e:1913 recomputes bit 7 as an even-parity bit whenever [0x26c6] is zero, then applies the [0x0936] framing. In those framings bit 7 carries no data, so capture reports the seven bits a receiving DTE would keep.

With that in place the diagnostic commands render their real pages. ATI and ATI0 return the product code, ATI1 the ROM checksum, ATI2 the RAM test result, ATI3 the product banner, ATI5 the stored-profile page, ATI6 and ATI11 link diagnostics, ATI7 the configuration profile, and ATI4 the full settings report:

USRobotics Courier V.Everything Settings...

   B0  C1  E1  F1  L2  M1  Q0  V1  X1
   BAUD=9600   PARITY=E  WORDLEN=7
   DIAL=TONE   ON HOOK   TIMER
   ...
   S00=001  S01=000  S02=043  S03=013  S04=010  S05=008  S06=002  S07=060
   ...
OK

Note that ATI5 renders its "NVRAM Settings" page from the RAM shadow at 0x095c, not from the serial EEPROM, which matches the call-graph finding below. Commands execute inside the original firmware: ATQ1 changes its quiet-mode profile byte and suppresses the result code, while ATD123 and ATA enter the line-control path. With no modeled line, an originating call follows the firmware's NO DIAL TONE path. DSP results separate completed bootstraps and transfer_commands from runtime mailbox_commands, with a mailbox_windows histogram of the latter.

The line-audio endpoint is the Courier ASIC's external C51 I/O frame, separate from both on-chip serial ports and the 80186 download window. Firmware reads the held ADC word twice from external I/O port 0x54 at program 0xb300 and 0xb304; the second read is copied into active sample cell 0x007f. Its matching per-frame OUT at program 0x8c24 writes the DAC word to external port 0xb2e5, sourced from output cell 0x00cb. TRCV (0x30) and DRR (0x20) are part of the ASIC/serial framing and address bookkeeping, not raw linear-PCM endpoints. Supply and capture mono signed-16 little-endian words after dial/answer activation with:

./courier run main211.xmf --instructions 9000000 --with-dsp \
  --dsp-rx-pcm line.s16le --dsp-tx-pcm reply.s16le --at ATDT123 --summary

dsp_bridge.serial_port reports the register values, access counts, last firmware PCs, queued/consumed input frames, and line-output counts. The modeled missing board-to-DSP dial-command handoff recognizes the firmware's parsed D command and drives 9.6 kHz DTMF frames through the C51's real OUT instruction. ATDT123 produces 697+1209, 697+1336, and 697+1477 Hz bursts. This establishes bidirectional waveform transport and reproducible tone output; the original datapump's internal command mailbox remains to be recovered.

The behavioral DAA can attach a disconnected, quiet, dial-tone, or ringing line. A dial-tone line seizes the hook relay, supplies 350+440 Hz audio to the recovered ASIC ADC, qualifies the supervisor's five-hit detector at RAM 0x0649, removes central-office tone, and starts the parsed digits on the already-active C51. --daa-line enables the DSP bridge automatically:

./courier run main211.xmf --instructions 9000000 \
  --daa-line dial-tone --at ATDT123 --summary

The original firmware then returns OK instead of NO DIAL TONE, and dsp_bridge.daa reports hook, line, detector, and generated-sample state. This is a firmware-derived behavioral DAA, not a claimed identification of the physical line-interface IC. Busy/reorder tone and carrier negotiation remain unmodeled.

For isolating the DTE online path from datapump completion, the diagnostic --force-online option publishes the modeled completion edge once the main loop is reached and marks the console as data mode:

./courier run main211.xmf --instructions 12000000 --with-dsp \
  --force-online --console

This does not claim that modem training succeeded. The result reports online_mode, data_rx_bytes, and data_tx_bytes; use it to test transparent post-CONNECT traffic while the real ASIC completion callback remains under investigation.

The silicon DAA as a register file

The line-interface chipset itself is modeled as registers rather than behavior, and it is on by default — the board has a DAA, and ATI7 reports a failure without one (below). --no-daa-codec turns it off; it also drops out on its own for a flash ROM, which carries no separable C51 payload for the DSP bridge the codec rides on. Modelling it costs about 20% of a run's wall time, since it brings the native C51 bridge up on runs that would not otherwise need it.

The board carries an Si3021 and an Si3014; docs/SI3038.PDF is the AC'97 sibling of that pair and is the only published register map here, so the model uses its addresses for the shared line-side fields.

That attribution is about the line interface. The part on the DSP's own serial port is a different one: a TI TLC320AC0x, identified from the board and confirmed by the C51's firmware, which uses bit 0 of each transmitted word to request the secondary frame that carries a control register — the AC0x protocol. See what is actually on the board. So CodecBringUp, which runs an SI3038 register sequence, models a part the DSP does not talk to; the line-side attribution is untouched.

./courier run main211.xmf --instructions 20000000 \
  --daa-line dial-tone --at ATA --summary

dsp_bridge.codec then reports the whole register file, the readiness byte, and the assembled line status:

"steps": ["register-reset", "sample-rate", "power-up", "ready",
          "gpio", "levels", "line-interface"],
"polls": 3,
"readiness": "0x0f", "link_up": true,
"loop_current_ma": 25, "loop_current_sense": 4,
"line_status": "0x0050"          FDT set, LCS[3:0] = 4

The seven steps are the datasheet's initialization procedure, including its readiness poll, and nothing in the Courier's firmware performs them: the 80186 writes ports 0x40..0x4e thousands of times and never reads them, and the C51's only external reads are the host mailbox window and the line ADC, so neither processor can see the readiness byte step 4 waits on. The sequence belongs to the interposed ASIC — the arrangement AN16 section 1.3 describes — and CodecBringUp stands in for it, one service frame per 100 ms.

There is no register-level read path from the firmware, so the model is driven rather than polled: hook and line state come from the behavioral DAA, ring bursts from the ring source, and loop-current sense, ring detect, frame lock, and the country settings come out of the registers. --daa-codec-line selects which line the part is strapped as (deciding whether readiness reads 0x0f or 0x33), and --daa-codec-rate programs register 40h, rounding to the nearest rate the PLL offers.

One thing the firmware does read is the DAA's identity, and ATI7 prints it:

./courier run main211.xmf --instructions 14000000 --at ATI7
Product ID             00345302        with --no-daa-codec: XX345302
DAA rev                0004            with --no-daa-codec: 0000

The supervisor's receive table stores mailbox tag 0x7b's data word at [0x287]. ATI7 prints that word as DAA rev, the self-test at 0x77eda appends " : DAA Failure (zero is Invalid)" when it is zero, and 0x8369d branches on it being 4 to print product ID 00345302 rather than the placeholder XX345302. Nothing was producing that message, so the firmware reported a DAA it considered invalid, which is why the codec is on by default rather than opt-in. The report goes out on the first DSP download, since a real part identifies itself at power up rather than at the dial/answer boundary; --daa-codec-revision changes the value, and 0 will reproduce the failure path. The 4 is read out of the firmware's own product-ID branch, not measured off a part.

Complete flash ROM images

rom-info describes a whole flash part rather than an update payload:

./courier rom-info IDSDL302.ROM

An XMF carries only the application, so where it lives is a modelling choice. A ROM ends with the 80186 reset vector, and the stub there programs the chip select that decodes the ROM before it jumps, so the image places itself. For the 1998 Courier V.Everything external ROM that gives flash at 0x80000..0xffc00, 128 KiB of RAM at 0x00000..0x20000, and the peripheral control block relocated into memory at 0x0ff00 — which is the window this harness already hooks.

It also carries the ~6 KiB boot block above the application that an update image never replaces: the hardware setup tables, the copy of itself to physical zero, the power-on read of the settings EEPROM, the whole-flash CRC, and a second copy of the SDL loader.

run takes a ROM as well, booting it from its reset vector:

./courier run IDSDL302.ROM --instructions 40000000 --int1-after 7

The peripheral timers are modelled from the instruction clock - the enable gate, the zero-compare-is-full-range rule, single-shot versus continuous, the sticky max-count bit, and the mask side of the interrupt controller - which is what carries the ROM past its timer self-test at 0x80444. It then reaches a tick wait whose period this firmware calibrates from an external INT1 edge rather than from a timer alone; --int1-after supplies one. courier_firmware_analysis.md has the full account, including where that sequence still stops, the cross-build confirmation of the latch driver, and every option switch.

ISDN Courier XMP images

Ie030002.xmp is an ISDN Courier update payload, and it is a different animal from an XMF: no product text header, and an obfuscated body.

./courier xmp-info Ie030002.xmp
./courier extract Ie030002.xmp extracted/Ie030002
File range Contents
0x00000..0x0007f 128-byte header: USR XMP\0 magic, three small fields, and a 0x70-byte table
0x00080..0xb807f 0xb8000-byte payload, every byte XOR 0x45

The key falls out of the image without any code analysis. Erased flash still dominates the payload, and the pad byte reads 0xba; 0xff ^ 0xba is 0x45. Decoding with it turns 0xff back into the most common byte, and the result carries the VRTX kernel banner (Copyright 1988, Ready Systems) and the ISDN rate-adaptation strings (SET_V110_ENTRY, V110_ATO).

The payload decodes to three programmed spans, the last being a two-byte word at the very top of flash:

Payload range Size
0x00000..0x5d320 381,728
0x64000..0xaab0c 289,548
0xb7ffe..0xb8000 2

It is an 80386 image, and it says so at payload offset 0x38, where it clears dr0..dr3 and dr7 — registers the 80186 supervisor does not have. The code around it programs a linear address into dr0, sets the local and global enable bits in dr7, and installs its own INT1 (#DB) handler at 4000:0148, so the firmware drives hardware breakpoints as a normal runtime mechanism. Note that this is vector 1, distinct from the 80186's INT1_VECTOR = 13 pin interrupt in timers.py.

Nothing here executes yet. What is loaded is the container and the decoded body; what is not modelled is the board. Two things stand out from the decode:

  • Debug registers. Unicorn does not deliver #DB from guest-programmed dr0..3, so the harness would have to match breakpoints itself.
  • The 0x70-byte header table at offset 0x10 is plaintext, not obfuscated, and plainly structured — a handful of 16-bit values recur through it — but its layout is not recovered, so xmp-info reports it verbatim as header_table_undecoded rather than inventing fields for it.

The load base is a modelling choice, as it is for an XMF. FLASH_PHYSICAL_BASE is set to 0x40000 because the boot code installs its INT1 handler in segment 0x4000; the header's load_hint field reads 0x40, which is consistent with that base in 4 KiB units, but nothing in the image confirms the unit.

No protected-mode entry appears in the decoded payload — no lgdt, lidt, lmsw, or mov cr anywhere in it. This is 386 code running in real mode, using 32-bit registers, 0x66/0x67 prefixes, and the debug registers.

ISDN Courier NAC images

Ie030002.nac is the same firmware in a different container, and it is not obfuscated at all. It is Intel HEX with the ASCII stripped out: each record is a length byte, a big-endian 16-bit address, a type byte, and that many data bytes. The big-endian address is the giveaway — everything else in these images is little-endian, but Intel HEX writes its address big-endian even on x86.

./courier nac-info Ie030002.nac
./courier extract Ie030002.nac extracted/Ie030002
File range Contents
0x00000..0x0001f 32-byte header
0x00020..0xcd1a6 Binary Intel HEX record stream
0xcd1a7..0xcd1a8 Two trailing bytes, e4 a0

Header fields:

Offset Contents
0x03 u32 record-stream length — exactly file size minus header minus trailer
0x08 Version triple 03 00 02, matching the Ie030002 file name: 3.0.2
0x0f Product tag IE(, the same tag the .sdl loader carries

The record types are the Intel HEX ones:

Type Count Meaning
0x00 42,023 Data
0x02 197 Extended segment address, big-endian, scaled by 16
0x03 1 Start segment address, 0ce0:0000
0x01 1 End of file

Unlike ASCII Intel HEX there is no per-record checksum byte; parsing without one consumes the stream exactly, from the end of the header to the EOF record.

The stream's very first record is a type 0x02 setting segment 0x4000, so the image places itself at physical 0x40000 — the harness does not have to assume a base for a NAC the way it does for an XMF. That independently confirms the base the XMP section above had to infer from the boot code's INT1 handler.

The two containers agree exactly. Flattening the NAC's 42,023 data records produces a 0xb8000 image at 0x40000 that is byte-for-byte identical to the XOR-decoded XMP payload, and the 82,879 bytes the NAC never paints are precisely the bytes that read as erased flash in the XMP. Two independently encoded containers reaching the same image is the strongest check available on both decodes. Re-check it with nac-info against the XMP decode when validating a new image.

What is not recovered: the two trailing bytes e4 a0. They are not a byte sum of the record stream and match none of the common CRC-16s (CCITT-FALSE, XMODEM, ARC, MODBUS, KERMIT, GENIBUS) over either the stream or the whole file, so nac-info reports them verbatim as trailer_undecoded.

The start segment address 0ce0:0000 is physical 0xce00, which is RAM well below the flash — the entry after the boot block relocates itself, consistent with the code at payload 0x300 loading 0x0ce0 into a segment register.

Board latches, front panel, and NVRAM

Every board output goes through one read-modify-write latch driver, recovered at physical 0x5e2b0 (set), 0x5e2e5 (clear), 0x5e335 (read an input port), and 0x5e294 (read the shadow). Callers pass AX = mask << 8 | index; the index table at 0x5e31c and the shadow bytes seeded at 0x5e26c give:

index port shadow contents
0 0x10 0x064d hook relay, settings-EEPROM bit-bang pins
1 0x12 0x064e indicators, error-blink code byte
2 0x14 0x064f indicators, board-ID strap drives
3 0x12 0x0650 second 0x12 signal group

Both entry points special-case AX == 0x0408 and AX == [0x065c]: the set path at 0x5e2b4 jumps into the clear body and the clear path at 0x5e2e9 jumps into the set body. 0x0408 is latch 0 bit 0x04, so the hook relay is asserted by driving its latch bit low. Latch 0 bit 0x01 is raised over exactly the same window (0x5db4e on seizure, 0x5e197 on release).

Every run now reports a panel block with the current latch values, the asserted state of each named line, off_hook, and a change trace:

i=2191703 port=0x10 value=0xf2 pc=0x5e317 +hook-relay
i=2191740 port=0x10 value=0xf3 pc=0x5e2e0 +off-hook-aux
i=2291289 port=0x10 value=0xf2 pc=0x5e317 -off-hook-aux
i=2291366 port=0x10 value=0xf6 pc=0x5e2e0 -hook-relay

Bits are only named where the firmware shows what the line does. Two runtime DTE lines are now named as well:

  • Latch 2 bits 0x01 and 0x80 are driven as one pair by 0x5de57: cleared together at 0x5de65/0x5de6b when the &C setting at [0x09e9] is zero and set together at 0x5de7d/0x5de83 otherwise. &C0 is "carrier detect always on", so the cleared level is the asserted one and these are the carrier-detect pair. Which one is the DTE pin and which is the front-panel lamp is not established, so they are reported as carrier-detect-a and carrier-detect-b.
  • Input port 0x12 bit 0x40 is DTR. 0x5e375 samples it, 0x5e395 and 0x5e3b5 re-poll it, the two transitions post supervisor events 6 and 7, and 0x5e887 turns a low reading into event 10 when S14 bit 0 is set.

The remaining indicator bits on 0x12 and 0x14 are reported under placeholder names with their driver-wrapper addresses in courier_emu/panel.py; mapping them onto front-panel legends still needs a physical reference.

Option switches

The board option switches are input bits on the same latch ports, sampled with the same mov ax, mask << 8 | index; call 0x2d4a form the straps use. Six are read while the profile is built at 0x63d31..0x63ec2 and the carrier-detect switch is read separately at 0x5e3cf. The firmware reads a closed switch as a low bit, so the sense is inverted, and each switch also records itself in the shadow word at [0x0659].

Every row below was confirmed by running ATI4 with that one input bit pulled low and diffing the profile the firmware prints, so the effect column is observed rather than inferred:

switch port/bit closed behaviour observed
result-codes 0x14 0x20 0x63e2e clears the quiet setting at [0x092f] Q0
quiet-answer 0x12 0x08 0x63e54 sets [0x092f] to 2 Q2
quiet-answer-alt 0x12 0x80 0x63e75 sets [0x092f] to 2 none — gated on capability bits 0x08 and 0x20 at 0x63e40
numeric-results 0x10 0x02 0x63e17 leaves [0x092e] clear V0
no-echo 0x12 0x10 0x63e93 leaves [0x092d] clear E0
dtr-override 0x12 0x20 0x63d48 leaves S14 at [0x094e] clear S14=000
carrier-detect-override 0x14 0x04 0x5e3e1 clears [0x09e9] &C0
no-auto-answer 0x14 0x10 0x63eb5 leaves S0 at [0x08de] clear S00=000

Three of these names are corrections. [0x08de] is S0, not a profile source, so that switch is the auto-answer switch and its closed position is the one that stops the modem answering; the switches previously called verbose and echo both disable those settings when closed. Names now describe what closing the switch does. Mapping them onto the switch numbers printed on the case still needs a physical unit.

--dip closes a switch and is repeatable; the first use replaces the default set, and --dip none leaves every switch open. result-codes is closed by default because a directly attached DTE wants result codes — with it open the modem is genuinely silent, which is the real behaviour and used to be papered over by writing [0x092f] directly:

./courier run main211.xmf --instructions 4000000 --at AT --dip none

Dedicated-line operation

A modem on a dedicated line has no DTE holding DTR up and no call setup to follow, so it needs DTR ignored and carrier detect held on. --dip-preset dedicated-line closes result-codes, dtr-override, and carrier-detect-override, and leaves no-auto-answer open so S0 keeps its flash default of 1 and the modem answers on the first ring:

./courier run main211.xmf --instructions 12000000 \
  --dip-preset dedicated-line --at ATI4

The firmware confirms all three in its own profile dump: &C0, S14=000, and S00=001.

Ring detection

The answer machine at 0x70fb4 polls input port 0x14 bit 0x02 with a direct in al, 0x14, and every state in it waits on an edge of that bit, so a line that never changes level parks it in its first state forever. That bit is now modelled: an idle line is not ringing, and --ring drives it with a cadence.

./courier run main211.xmf --instructions 40000000 \
  --ring --at 'AT#CID=1' --summary

The harness has no wall clock, so the cadence is converted from milliseconds through the instruction count. 0x70fe0 accepts a burst once the tick counter at [0x1d50] reaches the country minimum at [0x1f5c], which this build loads with 180.

That counter was once read as the calibration for the conversion: assume the burst reaching 180 is a 2 s North American ring, and one firmware tick is 10 ms and the instruction clock 1,111 per millisecond. Both figures are withdrawn. The tick is 5 ms, measured from the timer 0 compare each build programs on its own crystal, so 180 ticks is a 900 ms minimum qualification rather than a whole burst - and the derivation was circular anyway, since machine.py synthesizes the tick itself at tick_ms * INSTRUCTIONS_PER_MS. The instruction clock is 4,348 per millisecond, from the codec's own sample count. See Hardware time base and audio path.

With that cadence the answer machine qualifies bursts (0x70fe9), raises the ring-indicate line (0x70ff0), and posts its ring message (0x71026) into the supervisor event queue at 0x02e0. Two gates matter there:

  • [0x094e] is #CID, expanded from packed-config byte 11 of the parameter sector, and both ring message sites skip the post when it is zero. AT#CID=1 enables them.
  • [0x0287] bit 0x10 gates the second ring path, and it reads zero here.

What does not yet happen is the answer itself: the queued ring events are never acted on, with or without --with-dsp, so no RING reaches the DTE and the hook relay stays released. The consumer of that queue is the next thing to recover.

Answering

ATA reaches the same 0x5dbe7 line-detector wait that ATD does. Since an answering seizure has no dial tone to find, the DAA qualifies detector byte [0x0649] on a connected line for answer and keeps requiring dial tone for originate:

./courier run main211.xmf --instructions 40000000 \
  --at ATA --daa-line quiet --summary

That turns NO DIAL TONE into NO CARRIER, which is the correct answer to answering into silence: the line is seized and qualified, and training then fails for the reason the SIP section describes. Treating [0x0649] as the line-side detector rather than a dial-tone-only counter is an inference from the shared wait, not something the image states.

Board identification straps

The scan at 0x5bfc6 identifies the board by driving four latch lines low one at a time (latch 1 bit 0x02, latch 2 bits 0x40, 0x10, 0x20) and shifting input port 0x14 bit 0x08 into a four-bit code. 0x5c051 looks that code up in the table at 0x5c06b and 0x5c05c stores the result as the board capability byte at 0x0a02. Two capability bits are pinned down: 0x08 is "settings EEPROM fitted", tested by every NVRAM path, and 0x40 sends 0x5bb0f straight to the fatal blinker.

code capability code capability
2 0x29 9 0x28
5 0x14 12 0x28
7 0x22 13 0x22

Codes 11 and 14 map to 0x42 and 0x48, which carry the fatal bit; every other code is an empty table entry and 0x5c064 stores zero. --board-id drives the straps and rejects the codes the firmware cannot run on. It defaults to 2, the lowest code describing a board with an EEPROM and no fatal fault; none leaves the lines floating, which the firmware reads as no board at all.

Which of 2, 9, and 12 a given board revision actually straps is not recoverable from the image — they differ only in capability bit 0x01, whose meaning is not established. The default is a constrained inference, not a verified board ID.

Leaving the straps floating is not a state real hardware can be in, and the firmware treats it as a fault. Two visible consequences:

  • 0x667cb maps a zero or 0xff capability byte straight to result code 4, so ATI1, ATI2, ATI3, ATI7, ATZ and ATS30? answered correctly and then reported ERROR.
  • 0x82ea4 picks the product code from capability bit 0x08: a board with an EEPROM answers ATI with 3368, one without answers 3368A.

The settings store is a 93C66-class Microwire EEPROM (256 x 16) bit-banged on latch 0. The driver is at 0x5ccc0..0x5cdf9:

routine role
5b5e:16e0 read word; [0x8d2] = address, result in [0x8d3]
5b5e:1746 write word; [0x8cf] = address, [0x8d0] = data, EWEN/EWDS bracketed
5b5e:17c6 build and clock the twelve-bit command frame
5b5e:17d2 shift bits most-significant first
5b5e:1801 presence poll; input port 0x10 bit 0x08 must read high

5b5e:17c6 forms bx = ((opcode & 3) | 4) << 8 | address and rotates it left by four before clocking twelve bits, which is one pad bit, the start bit, two opcode bits, and an eight-bit address. Latch bits are 0x20 chip select, 0x40 clock, 0x10 data in on write and data out on read.

Attach a persistent image with --nvram; it is created blank (all ones, like an unprogrammed part) when the file does not exist and written back after the run:

./courier run main211.xmf --instructions 7000000 \
  --at AT --nvram settings.nv --summary

For a deterministic IDSDL302.ROM boot, the recovered six-record settings cache can instead be attached in memory, together with the +S register defaults that AT+SF loads - without them the DSP dials at zero level, as the board did. This leaves every other EEPROM word erased, and does not alter the blank --nvram behavior:

./courier run IDSDL302.ROM --instructions 60000000 \
  --tick-ms 10 --nvram-fixture idsl302 --at AT --summary

The 20 MHz 302/403 ROM serial adapter runs the firmware's attention detector, parser, and UART transmit path. See ROM serial execution for the tested board settings, captured 403 command, and autobaud limitations.

The fixture reverses all three byte encodings used for each redundant record; it is mutually exclusive with a persistent --nvram image.

nvram in the result reports reads, writes, erases, the write-enable latch, the programmed words, and a command trace.

Why the EEPROM stays untouched at boot

reads and writes both stay at zero through boot and plain command mode. That is the firmware's own behaviour, not a gap in the device model. Three separate findings account for it.

There is no boot-time NVRAM profile load. All eleven call sites for the two driver entries live in banked segment 0x81b8 (0x8374x, 0x8386x, 0x838b9, 0x84de8), and they are command handlers: a word-by-word diagnostic dump that prints through the resident character-output helpers, a six-word store whose last word is a CRC-8 over the previous four, and a config write at 0x84dc7 that parses a literal =PW and programs word 0 to 0x4000 or 0x0000. None of them is on the reset path. The working profile at 0x08de..0x095b is instead filled at boot from a 77-byte flash default table copied at 0x63b72, and the saved profile at 0x095c..0x09d9 is a plain RAM shadow (81b8:35ee saves, 81b8:3601 restores and re-applies).

The diagnostic and store paths are gated on [0x0a02] bit 3. That byte is the board capability code produced by the strap scan at 0x5bfc6, which drives four lines (latch 1 bit 0x02, latch 2 bits 0x40, 0x10, 0x20) low one at a time and shifts input port 0x14 bit 0x08 into a four-bit index, then looks the index up in the table at 0x5c06b. With that input floating high the index is 15, the table entry is 0x00, and 0x5c064 stores [0x0a02] = 0. Codes 2, 9, 12, and 14 yield 0x29, 0x28, 0x28, and 0x48, all of which carry bit 3. The boot gate at 0x5bbb5 branches on the same bit.

The persistent configuration lives in a separate parameter flash, not in the XMF image. The routine at 0x7e07c — reached by the harness's startup-crc milestone — scans four 4 KiB blocks from segment 0xf800 (physical 0xf8000..0xfbfff), checksums bytes 0x000..0xffd into [0x06fc], compares against the word at 0xffe, and keeps the block with the highest 32-bit version at 0xffa. main211.xmf maps at 0x40000..0xb7fff, so that region is empty here, ES comes back zero, and 0x7dffa skips the whole unpack. Bytes 0..4 of a valid block become [0x0a06..0x0a0a], and byte 4 becomes [0x0a03] — the capability byte that gates the profile restore at 0x6014f and selects whether 0x63b6d loads defaults into the stored profile at 0x095d instead of the working copy at 0x08df.

Synthesising a block confirms the mechanism: writing a 4 KiB record at 0xf8000 with a matching checksum makes the search return es = 0xf800 and load [0x0a03]. Reaching command mode from there needs more of the parameter block filled in than a stub provides, so the harness does not ship one; recovering a real parameter sector from hardware is what that path needs.

Parameter sector

The persistent configuration lives in a 16 KiB parameter flash searched at physical 0xf8000, which the XMF update image does not carry. The search at 0x7e07c walks four 4 KiB sectors, checksums bytes 0x000..0xffd, compares against the word at 0xffe, and keeps the sector with the highest 32-bit version at 0xffa. The winner is copied to 0x0a06 one byte for one, so sector offset i lands at RAM 0x0a06 + i:

offset RAM role
0x00 0x0a06 flags; bit 3 keeps [0x0a03] clear
0x01..0x06 0x0a07..0x0a0c country, features, type2, type1, unused2, unused1
0x11..0x1c 0x0a17..0x0a22 serial number, 12 ASCII characters
0x1d..0x2f 0x0a23..0x0a35 packed config, expanded at 0x64044
0x30..0x61 0x0a36..0x0a67 working-profile image, scattered at 0x6406f
0xffa 32-bit version
0xffe CRC-16/CCITT over 0x000..0xffd

The packed config is expanded through the (shift, mask) table at 0x63f8d into the 36 profile bytes 0x0932..0x0955; the profile image is scattered to 0x08de plus the 50 offsets listed at 0x63fd6. The serial number is read as nine characters at 0x0a17 plus three at 0x0a20 (0x835bb), and 0x77bb9 treats four 0xffff words as no serial fitted.

Dumping the real part is not practical, so parameters synthesises a sector the firmware accepts. It carries the firmware's own power-on defaults for the packed config and profile image, so only the fields you set change:

./courier parameters params.bin --serial 12345678 \
  --feature hst --feature fax --feature terbo --feature v34 --feature v90
./courier run main211.xmf --instructions 8000000 \
  --parameter-sector params.bin --at ATY14

That reproduces the configuration dump reported for a fully featured unit, and ATI7 renders the full profile including the serial number:

000,000,030,007,031,000

Product type           US/Canada Internal
Product ID             XX345302
Options                HST,V32bis,Terbo,VFC,V34+,V90,V92
Clock Freq             25 Mhz
Serial Number          12345678

The sector's first byte gates each unpacked field, applying it when the bit is clear, and --flags sets it. Bit 3 decides whether type1 reaches [0x0a03], and 0x8339f tests bit 0x04 of that byte before the ATY15 case is even reachable — so the default 0x08 is why that command answers ERROR. A sector with bit 3 clear and type1 carrying 0x04 makes it print the factory switch page instead, which reports all ten option switches as the firmware reads them:

./courier parameters params.bin --serial 12345678 --flags 0
./courier run main211.xmf --instructions 9000000 \
  --parameter-sector params.bin --at ATY15
CURRENT DIPSWITCH SETTINGS
DIPSWITCH #1   ON
DIPSWITCH #2   OFF
DIPSWITCH #3   ON
...

Feature bit 4 (value 16) is labelled x2 in archived notes for older Courier firmware, but on this 2002 build it gates V.90: 0x77d47 uses it to append ,V90 to the options list, and 0x82e7d uses it to select the 5608 product code instead of 3368. The options table does hold an x2 string at 733c:49d6, but nothing in the image ever loads it, so this firmware cannot report x2 at all.

The board identification straps select the enclosure ATI7 reports, which is a useful cross-check against a physical unit:

--board-id capability ATI7 product type
2, 9, 12 0x29, 0x28 Internal
5 0x14 Rackmount
7, 13 0x22 External

Note the tension with the default: codes 2/9/12 carry capability bit 0x08, the settings-EEPROM bit, but report Internal, while the External codes do not carry it. Capability 0x22 is also the one value 0x667cb special-cases as always returning OK. An external unit is therefore likely --board-id 7, which also changes the product code to the A suffixed form (5608A/3368A). Running ATI on real hardware settles it.

A modeled line: the digital ATA

--exchange puts a central office on the subscriber loop instead of a fixed --daa-line state. It is the network side of one line, entirely in the codec sample stream - no loop current, no hybrid, no two-wire pair, which is what makes it digital rather than an analog terminal adapter. It watches the hook, plays the tones the loop would carry, decodes the dialed number out of the audio the modem transmits, and routes the call:

./courier run main211.xmf --exchange \
  --exchange-number 5551212=answer --at "ATDT5551212" \
  --instructions 120000000
"exchange": {
  "state": "connected", "dialed": "5551212", "digits_decoded": "5551212",
  "outcome": "answer", "rings_delivered": 2, "calls": 2
}

Nothing hands it that number. The supervisor qualifies its line detector on the exchange's 350+440 Hz dial tone, the C51 puts DTMF on the line, and a Goertzel receiver in the exchange reads it back off the transmit stream. That is the difference from --daa-line dial-tone, which supplies a line state the harness chose and removes dial tone as soon as the model decides dialing has started - the gap recorded in courier_firmware_analysis.md under "What the dial sequencer is waiting on".

Routing the same number to busy instead stops the call at the tone, with no CONNECT: state=busy outcome=busy connected=false. The firmware does not print BUSY for it - call-progress tone detection is the DSP's, and no run has reached it - so what the exchange proves here is the line, not the report.

The states and what the loop carries in each:

state line leaves on
idle silence, on hook seizure
dial-tone 350+440 Hz continuous first digit, or 16 s to reorder
collecting silence #, a directory match, or 4 s interdigit
routing silence, 500 ms the outcome for the number
ringback 440+480 Hz, 2 s on / 4 s off answer after N rings
busy 480+620 Hz, 500/500 hang up
reorder 480+620 Hz, 250/250 hang up
answer-tone 2100 Hz 3 s, then connected
connected whatever peer_audio supplies, else silence release
ringing ring cadence toward the modem the modem going off hook

--exchange-number NUMBER=OUTCOME routes one number to answer, busy, reorder or no-answer; --exchange-outcome sets what an unrouted number gets, --exchange-answer-after the ringback cycles before pickup, and --exchange-answer-tone how long 2100 Hz runs before the call is handed on. LineExchange.ring() offers an incoming call, which drives the codec's ring detectors directly rather than through --ring.

The firmware places this call

With --exchange there is no DTE-level dial stand-in left. arm_dial_tones returns without reading the command, and every step below is the supervisor's own, running against the modeled line:

step what the firmware does where
parse reads the dial string out of its own command buffer 0x82652
seize drives the hook relay, board latch 0 bit 0x04, low 0x5e317
qualify counts its own five detector hits before accepting dial tone 0x5dbee
encode folds each character to a keypad index 0x6353c
dial sends 0x16:0000, the digit on tag 0x13, 0x16:0000 0x63553
time holds each tone and gap on its own [0x161] countdown 0x82342

--exchange therefore implies --tick-source dsp: the dial-tone wait, the tone duration and the interdigit gap all count on the supervisor's countdown chain, and unpaced the harness has to stand in for every one of them, which is the arrangement the exchange exists to replace. The line detector is modeled here rather than executed because the native core does not yet run the recovered DSP detector path end to end. The fallback answers the 0x7c poll with a low-band reading while the loop carries tone, and the supervisor counts its own five hits.

Nothing renders the digits. dsp_bridge.exchange.dialed - what the line actually heard - stays empty while ATDT5551212 is dialed. This was recorded here as "the tone generator is the ASIC's", and that is wrong: the three constant lanes the dial path sends alongside each digit, 0x19, 0x1a and 0x1b, are host-write tags whose handlers store into DSP data memory at 0x03ad, 0x0392 and 0x03f1. The tone parameters go to the C51, so the synthesiser is the datapump's, and what is missing is the harness reaching that code rather than an unmodelled generator elsewhere. See what the ASIC does. What the run does report is the sequence of commands the supervisor issued:

0016:0000  0013:0005  0016:0000   ...   x7   ->  commanded 5551212

each about 600 ms apart on the firmware's own timers. The exchange therefore hears silence, times out, and returns reorder. That is the honest state: the firmware places the call, and the board it is talking to cannot yet put a tone on the line.

One bug had to be fixed for any of it to run. The receive handler at 0x6ad6e takes a message tag from ports 0x58/0x5a and then its word from 0x5e/0x5c, and the bridge was serving the C51 status latch on those two ports even while a reply stood queued. The detector consumer at 0x5e4c4 read 0xffff for a reading the bridge had already answered, counted it as out-of-band, and hung up. Queued replies now own the data lanes.

What the C51 puts on the line

The core has no tone generator of its own. It once carried hand-written sin() in C++ - a DTMF pair generator, a 1300 Hz calling indicator and a 2100 Hz ANSam approximation - which substituted for the datapump's DAC output and discarded its accumulation to make room. That stand-in is gone, along with set_dtmf_digits and set_synthetic_line. The line now carries what the C51 computes through its AC01, and only that: on 3.0.13 that is the firmware's own DTMF, which the modeled exchange decodes as the dialed number (artifacts/dtmf-emulator-302-01).

An answered call reaches the datapump: ring the loop, answer it, and the recovered call overlay is entered and executes. What it writes is not audio. The frame ISR at 0x0228 keeps a 32-bit phase accumulator in @7c/@7d (0xfffc/0xfffd at DP 0x1ff), and reading 0xfffd as the DAC - which the core did - yields a linear ramp with a constant step, which measures as broadband noise. The word the ISR computes from it goes out through @7a to 0xffff, and that slot carries only two distinct values. Neither is a waveform. set_line_dac_slot makes the choice switchable so the question can be measured rather than assumed.

So the datapump runs, and where its PCM output goes is unresolved. The tblr at 0x022e reading a table based at 0x824d is the thread to pull. No run has produced V.21 at all; the harness only ever measured it.

Without --exchange nothing above applies: the --daa-line, link and SIP paths keep the stand-ins they had, including the parsed ATD, the faked line transition and the harness-generated digits.

Two instances on one line

link runs two instances sharing a two-wire line over a UNIX socket. Each side hands the far end one 100 ms frame of hook state and line audio and blocks for the far end's frame, so two independently executing runs stay on the same emulated clock without either knowing how fast the other goes. Both sides enter leased-line mode. The opposite option-switch presets leave switch 5 on at side A so it answers, and off at side B so it originates:

./courier link main211.xmf --instructions 40000000 --summary

By default both sides receive AT&L1. --a-at and --b-at change what each side is told to do, and run takes --line-link PATH plus --line-listen directly if you would rather drive the two processes yourself. The link implies --with-dsp and supersedes --daa-line: the far end's hook state is the line state.

The call comes up at the line layer. Each side reports the other off hook, both qualify the line detector, and each exchanges the same frame count:

a NO CARRIER  frames=354 peer_off_hook=True
b NO CARRIER  frames=354 peer_off_hook=True

It gets no further, but the original all-zero-DAC diagnosis is obsolete. The call overlay now loads at the ASIC service boundary, keeps IRQ 7 active, and produces role-dependent candidate TDM output while consuming peer words. The remaining issue is framing the overlay's 0xfffe/0xfffd slots (and its native TRCV/TDXR activity) into the physical codec stream correctly enough for the caller to qualify the answer signal. See courier_firmware_analysis.md for the current slot trace.

Pacing the supervisor's countdown chain

--tick-source dsp takes both sides further, and is available on run too. It drives the supervisor's countdown chain from the DSP frame interrupt, one tick per frame, which is the only arrangement tried here that leaves both of the firmware's mutual watchdogs quiet. It is off by default: the 1:1 ratio is a choice inside the band those watchdogs allow rather than a measurement, and the edge it delivers is one the interrupt controller has masked.

./courier link main211.xmf --instructions 40000000 --tick-source dsp --summary

With the chain running, the line-detector poller the chain carries runs too. The bridge answers its 0x7c00 request with a reading in the low band, so the firmware counts its own five hits at [0x649]; whenever the chain is paced the harness stops writing that byte, and stops zeroing the [0x289] wait it is counted inside. dsp_bridge.detector_replies reports how many requests were answered.

Both sides then leave command mode:

a OK  ticks=9141 detector_replies=44 frames=357 peer_off_hook=True
b OK  ticks=9141 detector_replies=44 frames=357 peer_off_hook=True

and swap the DTE callback table acdf,1fce,a8d9 for 50ad,18e3,4cac, which is a different front end from the command-line collector. OK is not a call result code, though, and there is still no carrier on the line behind it: this is the supervisor acting on state the harness supplied, not two modems that trained. The same option finishes ATI11, which previously stopped after "Modulation", and takes ATI10 to its "Strike a key when ready" pager.

The line carries no call setup, which is what a dedicated line is: both ends are connected and each simply sees the other seize. Ring cadence is modelled separately (--ring) and does not yet reach an answer, so an originate/answer call over the link is not available.

The window word 0x50 is not the datapump's command port

The C51 has no external IN for 0x50 at all. Data addresses 0x50..0x5f are reserved on a C5x, this core decodes them as external I/O, and the site at program 0x8c1f is a BIT @50, 6 inside the per-sample service routine. Its TC result is discarded by the CLRC TC at 0x8c3d with no consumer in between, so the word is read and thrown away. Three checks say the same thing from the other side:

  • Presenting each of the twelve header values the supervisor actually sends at window words 0x50/0x51 leaves a 3.4 M-instruction C51 run byte-identical in every counter, including where it stops.
  • The C51's IMR is zero after boot, so no host interrupt can reach it either.
  • Applying all 2,274 of a run's runtime messages as host_write(header, data) into C51 data space changes nothing.

So there is no host-to-datapump command path in the resident program, and "recover the 0x58..0x5e to C51 0x50/0x51 valid/ack timing", which earlier notes named as the next step, is not it. The supervisor's runtime traffic is a real channel — 2,274 two-word messages with a valid/ack handshake on port 0x1c, and the 0x40..0x4e window used only for the two program downloads — but whatever consumes it on the board is not the C51 code these images run.

What the datapump is doing instead

Taking instruction boundaries from a run rather than decoding statically, the whole of what the C51 executes in steady state is 167 instructions, one pass is 169, and the loop head is at 0x0cb1 — inside the bank the supervisor downloads. The datapump is resident and idle, not un-entered, and it uses about 6% of the cycles a 25 MHz part has per 9.6 kHz sample.

Every pass ends with BIT *, 4 on [0x00cc] and a CC 0xb4d4 on the result, and [0x00cc] is zero on every sample of every run. [0x00cc] is the datapump's own status word — the low half of a 32-bit value carried from sample to sample through [0x7e]:[0x7d] and ACCB, holding 0x0555_0000 throughout — and 0xb4d4 turns out not to be code at all but a numeric table, so that conditional is not the way in.

Interrupts are enabled — the reset code sets IMR = 0x002a and clears INTM — and of the sixteen, only number 7 changes anything when raised. That is not the datapump waking up: PMST.IPTR is zero, so the vector is program 0x0010, which is inside the reset code, and driving the interrupt partially reboots the C51. Almost 6,000 of the instructions it adds are below 0x00d0.

There is no vector table in this image to point it anywhere better. IPTR can only place one on 32 two-kiloword boundaries; the longest run of consecutive two-word branches at any of them is a single slot, and nothing table-shaped exists anywhere else in the image either. The area is never rewritten: across 600,000 instructions of startup the only program-memory instruction executed is one BLPD, which reads rather than writes.

Nor in any other image here. All fifteen — six XMFs, four XMDs, the ISDN ROM, .nac, .sdl and .xmp — scanned in both byte orders come up empty once the handler word is required to vary; the long runs are filler or sequential CALL code. Every XMF's DSP payload instead begins at file 0x2f0 with reset code, identical across main211, main2205 and 3453Bv2.1.1, and a different variant in the four 2.3.x builds whose first act is an external write to I/O port 0x8057 and which programs different wait states (PDWSR 0x2000 against 0x000a). So the vector area holding reset code is a property of every build in the tree, not a quirk of one image, and those wait-state values are the one direct statement about the memory map available here.

The reading that fits is that the C51 is in microcomputer mode, its program 0x0000..0x0fff is on-chip ROM holding both the vector table and the bootstrap that receives the download, and neither is in this image — so the assumption that the downloaded segment begins at program 0x0000 puts the downloaded init on top of the vectors.

The C51 memory map, and what the wait states say

The core used to parse MP/MC, OVLY and RAM out of PMST and act on none of them. It now decodes both spaces as the C51 actually lays them out: program is on-chip ROM below 0x1000 when MP/MC is low, DARAM B0 at 0xfe00 under CNF, external otherwise; data is registers below 0x0060, DARAM at B2 0x0060, B0 0x0100 (unless CNF moves it) and B1 0x0300, external from 0x0800 up, and reserved in the gaps at 0x0080..0x00ff and 0x0500..0x07ff. The C51 has no SARAM at all, so PMST.RAM and PMST.OVLY are don't-cares on this part.

The wait-state registers are decoded too, and they answer the MP/MC question the images could not. Both firmware families write CWSR 0x0010, which puts every space on the plain 0/1/2/3 scale, and then:

2.1/2.2  PDWSR 0x000a   program 0x0000..0x7fff  2 wait states
         IOWSR 0x0001   io      0x0000..0x1fff  1
2.3.x    PDWSR 0x2000   data    0x8000..0xbfff  2 wait states
         IOWSR 0x0101   io      0x0000..0x1fff  1, io 0x8000..0x9fff  1

Wait states only apply off-chip, so a non-zero field is the firmware saying it expects external memory there. The 2.1/2.2 boards put program 0x0000..0x7fff off-chip — exactly the span of the 30,172-word segment the supervisor downloads — which means MP/MC is high and there is no boot ROM under the download. The pin now defaults to high for that reason rather than by convention. The 2.3.x boards need no program wait states at all and put their slow external memory in data space instead.

Every run reports dsp_bridge.dsp_memory_map with the mode bits, the wait-state decode and per-region access counts. One of those counts is worth reading on its own: about 700,000 data accesses a run land in the C51's reserved windows, and they are the frame-block cells [0x00ca]–[0x00cd], including the line-DAC source and the gate above. On silicon those addresses hold no storage. courier_firmware_analysis.md has the rest.

Minimal SIP dial-out

--sip-server attaches the DAA to a small UDP SIP user agent and enables both the DAA and DSP automatically. Parsed ATD digits become the destination URI; the client supports an unauthenticated INVITE or one MD5 Digest retry after 401/407, SDP with PCMU payload 0, ACK/BYE, and bidirectional RTP. The modem's 9.6 kHz line stream is converted to/from 8 kHz PCMU. The current DTMF assist is inserted at the recovered C51 DAC write, so it travels as ordinary in-band audio; it is not yet evidence that the firmware datapump entered originate mode.

Keep the password out of command history by putting it in the environment:

export COURIER_SIP_PASSWORD='your-password'
./courier run main211.xmf --instructions 12000000 \
  --sip-server pbx.example.net:5060 --sip-username 6001 \
  --sip-target 'sip:{number}@pbx.example.net' --at ATD123 --summary

dsp_bridge.sip reports the target, response status, dialog state, RTP endpoints/counters, and a bounded event trace; it never includes the password. This deliberately minimal client is UDP/IPv4 and PCMU-only. It does not yet REGISTER, use SIP/TLS, negotiate other codecs, send RFC 2833 events, or turn SIP failure responses into Courier BUSY/NO ANSWER result codes.

A live 6000-to-7800 validation completed Digest authentication, received 200 OK, and carried 1,152 inbound and 507 outbound RTP packets, while the Courier still returned NO CARRIER. The supervisor emitted 30 two-word runtime control messages on ports 0x58..0x5e and none of them reached a datapump. The blocker is below SIP rather than in its duration or RTP transport, and it is not the host-latch timing earlier notes named: see "The window word 0x50 is not the datapump's command port".

The result includes CPU registers, the first 128 I/O/MMIO operations, complete per-address event counts, the hottest code addresses, and the final execution path. It also records supervisor-entry, dsp-transfer, startup-crc, and main-loop milestones; a run that reaches the normal dispatcher reports status: main-loop. Unknown input ports return all ones. Input responses and output latches are separate, matching hardware such as DSP command/status port 0x1e; --port sets only the input response. This intentionally makes unmodeled hardware visible instead of silently pretending it exists.

On macOS, a native Unicorn library can be selected with --libunicorn /path/to/library/directory. The worker boundary converts native signals into a clean CLI failure rather than crashing the controlling process.

Current boundary

The 80186 and C51 are lock-stepped at their recovered 20/25 MHz ratio. The supervisor's DSP bootstrap is reconstructed from ports 0x40..0x4e, verified byte-for-byte against the XMF C51 boot segment, and published to the native DSP through the recovered mailbox. The DTE serial path can inject commands and capture firmware-generated result text. The ASIC line frame now transports 9.6 kHz input/output samples and captures dial tones. Remaining device work is the original datapump command mailbox, complete 80186 peripheral timing, and unexercised C51 opcode forms. The silicon DAA's ring, loop-current, and frame lock state is modeled at register level under --daa-codec; its revision reaches the firmware through mailbox tag 0x7b and ATI7, but no read path to the line-side status fields has been found, so those are still unconsumed. The board latches, front-panel signal lines, and the Microwire settings EEPROM are modeled. What remains on the settings side is a recovered parameter-flash sector for 0xf8000 and front-panel legends for the unnamed indicator bits; there is no boot-time NVRAM profile load in this firmware to model.

Quad CPU AT terminal

For the current server answer attempt, see Quad server bring-up. The probe can now boot from the QF archive and records the watchdog-induced NO CARRIER path. CPU/DSP call control remains incomplete; it is not yet a negotiation peer.

The QF060003 modem now executes AT → OK with an explicit byte-terminal adapter. Run PYTHONPATH=. .venv/bin/python tools/probe_quad_at.py to boot the controller, load a modem, and verify OK, ERROR, then OK through its real firmware parser. See the measured transcript and adapter limits. Raw-pin autobaud remains incomplete. The Quad C50 endpoint now boots the resident streamed by this CPU and exposes a digital-call timeslot with one opaque 8-bit G.711 codeword in each direction at 8 kHz. connect_digital_call selects mu-law (0xff) or A-law (0xd5) idle fill; receive_g711 and transmit_g711 are the byte-exact ingress and egress surfaces.

The captured QF060003 DSP's stock DTMF path now runs too. It executes the QF selector at 0x8de0, oscillators at 0x8e54/0x8e60, sine helper at 0x92da, mixer at 0x82be, and serial ISR at 0x83e1; no generated DSP program or host oscillator supplies its samples. Run PYTHONPATH=. .venv/bin/python -m courier_emu.quad_audio --ram artifacts/quad-identify-20260910/ram.bin --output /tmp/qf-dtmf to render and measure all sixteen stock keypad tones.

The captured resident also contains QF's own G.711 expander and compressor. The component runner executes its DTMF generator, either compressor branch, and its byte serial ISR, producing raw 8 kHz .g711 streams without a host codec. The chassis call-control request that arms this path remains unfinished; see docs/quad-dsp-pcm-path.md.

Its stock answer-signal family is executable as well: 2100 Hz ANS, ANS with periodic phase reversals, ANSam with the resident's 15.05 Hz amplitude modulator, and ANSam with phase reversals. Run PYTHONPATH=. .venv/bin/python tools/probe_quad_answer_g711.py to emit every variant through both the QF A-law and mu-law compressor branches and serial ISR. Raw .g711 streams and decoded WAV previews are written under artifacts/quad-answer-g711-20260910/.