20 MHz ROM serial execution

The 302/403 CPU-only harness has a byte-oriented terminal adapter. It enters the ROM's existing attention detector, which recognizes A then T, collects the command body, calls the original parser, and generates the response. Output is captured only when firmware writes the integrated UART's S0TBUF (ff6a); entering a character-output routine does not fabricate output.

For the bundled 302 image:

./courier run IDSDL302.ROM --instructions 60000000 \
  --tick-ms 5 --board-id 7 --nvram-fixture idsl302 --at AT --summary

The captured 403 image can be used with the same options:

./courier run artifacts/courier-board-21210-capture-403/courier-board.rom \
  --instructions 60000000 --tick-ms 5 --board-id 7 \
  --nvram-fixture idsl302 --at AT --summary

The fixture is a recovered 302 settings fixture, not a captured 403 EEPROM. UART output may carry parity in bit 7; mask with 0x7f to interpret its ASCII text. The tests retain raw bytes and also assert that their count equals the UART's actual transmitted-byte count.

What the adapter supplies

courier_emu/rom_serial.py locates the callback table's RX ISR, attention handler, command dispatchers, mode byte, and output-routing flag from the resident instructions. It checks the command dispatcher's event-1 transition before accepting a layout. Unknown or incomplete layouts do not enable this adapter.

Resident item 302 captured 403
RX/TX/command table 026a 0164
UART RX ISR, segment 8000 0f23 0f54
A attention detector f170 f1a0
Ready command dispatcher 931d 93b0
Dispatcher after A 93b0 9443
Mode byte 033e 0237
Output-routing flag 0ea7 0d93

At the first queued byte after the existing boot delay, the adapter selects command mode and the attention handler, and disables the separate buffered output route. It supplies bytes through this image's integrated-UART ISR. After a command, queued input waits until the firmware returns to its ready state; the adapter then reselects the attention handler. It does not inspect command text or construct result strings.

This remains an explicit substitute for raw-pin autobaud in a CPU-only run. It does not establish cycle-accurate baud detection, DSP startup, or a working telephone connection. Timing still uses the harness's instruction-based boot and character delays.

Hardware-facing corrections

The terminal remains connected after its input queue drains. Previously the last carriage return also deasserted DTR while firmware was processing the command.

The resident ROM switch wiring differs from the XMF supervisor. In particular, its profile builder reads result-code enable at port 12h, bit 0 (selector 3, mask 01h), whereas XMF reads port 14h, bit 5. Applying the XMF wiring to these ROMs left Q1 selected and suppressed otherwise valid responses. The panel now selects the resident mapping for recognized ROMs.

The prior workaround forced a 302 collector and ISR into both layouts, skipped attention recognition, and redirected output to a RAM buffer. That block and its character-routine capture hook have been removed. The earlier failure analysis in rom-dte-path.md describes the pre-fix behavior.

Regression coverage

tests/test_rom_serial.py checks actual UART responses, complete consumption of queued input, repeated commands, and Q1/Q0 behavior. The layout tests cover both resident builds and reject incomplete signatures. The XMF callback regression checks that its existing serial path still works.

Validation on 2026-09-06: the focused ROM serial, serial callback, layout, and panel suite passed 31 tests and 8 subtests. Both ROMs completed AT, ATI, ATQ1, ATQ0, AT with four OK responses and no response to Q1. Captured 403 returned identification 5607A. These tests executed Unicorn outside the filesystem sandbox because its sandboxed memory mapping crashes on this host before firmware starts.