Commit Graph
8 Commits
Author SHA1 Message Date
jthedering 90ee2b0aa9 Version 0.9
Added: Filter type "IIR", which allows to specify a user-defined IIR filter of arbitrary order with custom coefficients.
Improved: For playback devices, the APO is now installed both as GFX (post-mix) and LFX (pre-mix) APO. Normally the filtering happens in GFX, but the command "Stage" allows to select LFX to apply effects based on the number of input channels.
Added: Expression language. The commands "If", "ElseIf", "Else", "EndIf", "Eval" and inline expressions allow to change the filter behaviour based on runtime conditions.
Added: Command "Copy", which copies audio data between channels.
Added: Command "Delay", which delays the audio on the currently selected channels.
Improved: Configuration files are now locked exclusively for writing while reading them.
Improved: There is now a transition (10 ms) from old to new configuration after loading.
Improved: Substantial internal restructuring to improve extensibility and maintainability. Filtering commands now work exactly in the order they were specified.
Fixed: When the microphone input was in stereo but the application requested a mono stream, the audio was heavily distorted.
Fixed: The sine sweep generated by the Benchmark application had floating-point precision issues leading to severe artifacts when certain filters were applied.
2014-08-10 18:35:59 +00:00
jthedering e0016d941c Fixed: Newer drivers with registry values introduced in Windows 8.1 were treated incorrectly in earlier versions of Windows. 2013-12-18 21:29:51 +00:00
jthedering a89f649009 Version 0.8.1
Fixed: Windows 8.1 is now supported.
Added: Filter types LSC and HSC that allow specifying the shelf slope with center frequency, unlike LS/HS 6/12db which use corner frequency.
2013-11-04 21:46:39 +00:00
jthedering e2d5e64f21 Added: All remaining filter types (LP(Q), HP(Q), LS(6/12dB), HS(6/12dB), NO, AP) of RoomEQWizard's "Generic" equalizer. Syntax is compatible to REW's filter text file, of course. 2013-05-14 19:22:04 +00:00
jthedering 3dab99a85a Improved: The benchmark application now has a real command line interface. To see the available options, type "Benchmark.exe -h" . 2013-04-30 20:07:56 +00:00
jthedering ef61580c19 Added: Support for having individual configurations for multiple devices. This is possible via the new command "Device" that allows to select the output devices to which the following commands (filters etc.) should be applied. The Configurator got a new button to generate a Device command for the selected connection(s). 2013-02-03 12:54:20 +00:00
jthedering 113debf439 Improved: Using floating point model fast instead of precise, which leads to a computation time reduction by approx. 1/3. 2012-11-06 19:02:18 +00:00
jthedering 9a97b96181 2012-09-18 22:13:36 +00:00