Files
hardware/firmware/test
Claude d5f9e0bd2d Auto-baud: don't lock on a single character
A rate too fast can split one character (a lone CR, as Enter sends on
many terminals) into two "characters", which passed the 2-character
rule: a lone CR locked onto the wrong rate in 80% of trials. Now the
rate is chosen first, and the 2 characters are counted only at that
rate, so one character waits.

Tests: one-character cases (CR, LF, 0x55, 0xFF...) at every rate must
not decide; CR LF and CR CR must lock and decode at every rate. Docs
note that Enter (CR LF), or Enter twice on a CR-only terminal, is
enough to learn the rate.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_013PRsUCpxazyipPn5UGGkF8
2026-10-18 01:36:52 +00:00
..