Files
courier-emu/tests/test_cli.py
T
Cryan209andClaude Opus 5 9558d77bd1 Run two instances on one shared line
link starts both sides of a dedicated line over a UNIX socket. Each side hands
the far end one 100 ms frame of hook state and line audio and blocks for the
far end's frame, which keeps two independently executing runs on the same
emulated clock without either knowing how fast the other goes. The far end
going off hook is the whole of call setup on a dedicated line, so the link
drives each side's DAA line state directly and supersedes --daa-line.

Both sides answer, both see the other seize the line, both qualify the line
detector, and both exchange the same frame count. Neither connects, and the run
localises why: over 40M instructions each C52 wrote 271,869 line samples that
were all zero while its command poll at port 0x50 read 0xffff every time. The
datapump never receives a command, so there is no carrier for the far end to
train against. That is the same supervisor-to-C52 runtime latch protocol the
live SIP call already stalled on, now reproducible without a PBX.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-05 14:09:39 +12:00

278 lines
11 KiB
Python

from __future__ import annotations
from contextlib import redirect_stdout
from io import StringIO
import json
from pathlib import Path
import tempfile
import unittest
from courier_emu.cli import main, ring_cadence
from courier_emu.parameters import FEATURE_BITS, ParameterSector, features_value
ROOT = Path(__file__).resolve().parents[1]
class CliTests(unittest.TestCase):
def test_info(self) -> None:
output = StringIO()
with redirect_stdout(output):
result = main(["info", str(ROOT / "main211.xmf")])
self.assertEqual(result, 0)
info = json.loads(output.getvalue())
self.assertEqual(info["entry"], "5b5e:0410")
self.assertEqual(info["error_blink_target"], 0x5C74A)
self.assertEqual(
[segment["origin"] for segment in info["dsp_program_segments"]],
[0, 0xDE83, 0x8000],
)
def test_dsp_reaches_stable_service_loop(self) -> None:
output = StringIO()
with redirect_stdout(output):
result = main(
["dsp-run", str(ROOT / "main211.xmf"), "--instructions", "20000"]
)
self.assertEqual(result, 0)
run = json.loads(output.getvalue())
self.assertEqual(run["status"], "stable-loop")
self.assertEqual(run["error"], "")
self.assertGreater(run["instructions"], 10_000)
self.assertLessEqual(run["recent_unique_pcs"], 256)
def _run_command(self, command: str, instructions: int) -> dict:
output = StringIO()
with redirect_stdout(output):
result = main(
[
"run",
str(ROOT / "main211.xmf"),
"--instructions",
str(instructions),
"--at",
command,
"--summary",
]
)
self.assertEqual(result, 0)
return json.loads(output.getvalue())
def test_identify_command_returns_the_product_code(self) -> None:
# 0x82ea4 picks the product code from capability bit 0x08, the same
# settings-EEPROM bit the NVRAM paths test: a board with an EEPROM
# answers 3368, one without answers 3368A.
run = self._run_command("ATI", 2_400_000)
self.assertEqual(run["status"], "main-loop")
self.assertEqual(run["serial_text"], "\r\n3368\r\n\r\nOK\r\n")
def test_board_dependent_commands_return_ok(self) -> None:
# 0x667cb maps a zero or 0xff capability byte straight to result code 4,
# so with the identification straps floating these answered correctly
# and then reported ERROR.
for command in ("ATI2", "ATI3"):
with self.subTest(command=command):
run = self._run_command(command, 4_000_000)
self.assertEqual(run["panel"]["board_capability"], 0x29)
self.assertTrue(run["serial_text"].rstrip().endswith("OK"))
def test_floating_straps_still_report_no_board(self) -> None:
output = StringIO()
with redirect_stdout(output):
result = main(
[
"run",
str(ROOT / "main211.xmf"),
"--instructions",
"4000000",
"--board-id",
"none",
"--at",
"ATI2",
"--summary",
]
)
self.assertEqual(result, 0)
run = json.loads(output.getvalue())
self.assertIsNone(run["panel"]["board_capability"])
self.assertTrue(run["serial_text"].rstrip().endswith("ERROR"))
def test_opening_the_result_code_switch_suppresses_them(self) -> None:
# 0x63e2e only clears the quiet setting at [0x092f] when that switch
# reads closed, so the open position is a genuinely silent modem.
output = StringIO()
with redirect_stdout(output):
result = main(
[
"run",
str(ROOT / "main211.xmf"),
"--instructions",
"4000000",
"--dip",
"none",
"--at",
"AT",
"--summary",
]
)
self.assertEqual(result, 0)
run = json.loads(output.getvalue())
self.assertEqual(run["status"], "main-loop")
self.assertEqual(run["serial_text"], "")
self.assertEqual(run["panel"]["dip_switches"]["result-codes"], "open")
def test_ring_cadence_defaults_either_half(self) -> None:
self.assertEqual(ring_cadence(None), (2_000, 4_000))
self.assertEqual(ring_cadence("1500:3000"), (1_500, 3_000))
self.assertEqual(ring_cadence(":3000"), (2_000, 3_000))
with self.assertRaises(ValueError):
ring_cadence("1500")
def test_dedicated_line_preset_forces_carrier_detect_on(self) -> None:
# 0x5e3cf reads that switch straight into the &C setting, so the
# profile the firmware prints is the check on it.
output = StringIO()
with redirect_stdout(output):
result = main(
[
"run",
str(ROOT / "main211.xmf"),
"--instructions",
"12000000",
"--dip-preset",
"dedicated-line",
"--at",
"ATI4",
"--summary",
]
)
self.assertEqual(result, 0)
run = json.loads(output.getvalue())
self.assertIn("&C0", run["serial_text"])
self.assertIn("S14=000", run["serial_text"])
switches = run["panel"]["dip_switches"]
self.assertEqual(switches["carrier-detect-override"], "closed")
self.assertEqual(switches["dtr-override"], "closed")
# Auto answer stays on: the switch that would disable it is open.
self.assertEqual(switches["no-auto-answer"], "open")
self.assertIn("S00=001", run["serial_text"])
def test_the_ring_detector_follows_the_configured_cadence(self) -> None:
# The answer machine at 0x70fb4 polls input port 0x14 bit 0x02 and
# every state waits on an edge, so the run has to see whole bursts.
output = StringIO()
with redirect_stdout(output):
result = main(
[
"run",
str(ROOT / "main211.xmf"),
"--instructions",
"30000000",
"--ring",
"--ring-start",
"8000",
"--summary",
]
)
self.assertEqual(result, 0)
run = json.loads(output.getvalue())
self.assertEqual(run["ring"]["on_ms"], 2_000)
self.assertEqual(run["ring"]["off_ms"], 4_000)
self.assertGreaterEqual(run["ring"]["bursts_delivered"], 3)
def test_two_linked_instances_hold_one_line_open(self) -> None:
# Both sides answer into the same line: each sees the other seize it,
# each qualifies the line detector, and both exchange the same number
# of frames because the link is what keeps their clocks together.
output = StringIO()
with tempfile.TemporaryDirectory(dir="/tmp") as directory:
with redirect_stdout(output):
result = main(
[
"link",
str(ROOT / "main211.xmf"),
"--instructions",
"20000000",
"--socket",
str(Path(directory) / "line.sock"),
"--summary",
]
)
self.assertEqual(result, 0)
run = json.loads(output.getvalue())
for side in ("a", "b"):
with self.subTest(side=side):
bridge = run[side]["dsp_bridge"]
self.assertEqual(run[side]["status"], "main-loop")
self.assertTrue(bridge["daa"]["off_hook"])
self.assertTrue(bridge["line"]["peer_off_hook"])
self.assertTrue(bridge["daa"]["detector_qualified"])
self.assertGreater(bridge["line"]["frames"], 0)
self.assertIsNone(bridge["line"]["error"])
self.assertEqual(
run["a"]["dsp_bridge"]["line"]["frames"],
run["b"]["dsp_bridge"]["line"]["frames"],
)
# The call is up at the line layer and no further: the C52 never gets a
# datapump command, so every sample either side puts on the line is
# silence and both report NO CARRIER.
for side in ("a", "b"):
self.assertEqual(run[side]["dsp_bridge"]["serial_port"]["line_tx_nonzero"], 0)
self.assertIn("NO CARRIER", run[side]["serial_text"])
def test_synthesised_sector_reproduces_the_reported_dump(self) -> None:
# A real parameter sector cannot be dumped, so this builds one carrying
# the configuration an x2-enabled unit reports and checks the firmware
# prints it back, along with the serial number and the x2 product code.
with tempfile.TemporaryDirectory() as directory:
path = Path(directory) / "params.bin"
ParameterSector(
features=features_value(tuple(FEATURE_BITS)), serial="12345678"
).save(path)
for command, expected in (
("ATY14", "000,000,030,007,031,000"),
("ATI", "5608"),
("ATI7", "12345678"),
):
with self.subTest(command=command):
output = StringIO()
with redirect_stdout(output):
result = main(
[
"run",
str(ROOT / "main211.xmf"),
"--instructions",
"8000000",
"--parameter-sector",
str(path),
"--at",
command,
"--summary",
]
)
self.assertEqual(result, 0)
run = json.loads(output.getvalue())
self.assertEqual(run["status"], "main-loop")
self.assertIn(expected, run["serial_text"])
self.assertTrue(run["serial_text"].rstrip().endswith("OK"))
def test_settings_report_is_captured_once_per_byte(self) -> None:
# The transmit routine re-enters itself while the integrated UART
# reports busy. Capturing at the entry recorded one copy of the pending
# byte per spin, which filled the 64 KiB cap with carriage returns.
run = self._run_command("ATI4", 3_000_000)
self.assertEqual(run["status"], "main-loop")
self.assertFalse(run["serial_truncated"])
text = run["serial_text"]
self.assertIn("USRobotics Courier V.Everything Settings", text)
self.assertIn("BAUD=9600", text)
self.assertIn("S00=001", text)
self.assertIn("S73=121", text)
self.assertTrue(text.rstrip().endswith("OK"))
# Bit 7 is the parity bit in this framing, not data.
self.assertTrue(all(character < "\x80" for character in text))
if __name__ == "__main__":
unittest.main()