The gain is not computed. a0ab1 reads [0x0cd9] for tag 1a and a0ac4 reads [0x0cdb] for tag 1b; traced across a dial each fires once with bx = 0000, and both cells read zero. Nothing in the image writes either by absolute address - those two reads are the only references. Neighbours in the same block are populated by the byte copy at a0907, which walks a table selected by [0x0c9e] into 0ca7, and [0xca7] and [0xcf9] hold 55 and 32 accordingly. But watching every write into 0cd8..0cdc shows the copy never reaches them: only a boot write, a clear at 804c6, and the 5555/aaaa RAM test appear. Whether the hardware also has zero there, or a real boot fills them, is one ATGLK2 read away on the board that runs this image. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
33 KiB
What gates the datapump dispatch on IDSDL302
ata-sip-line.md got the board firmware to dial a real number
over SIP: the DSP generates the DTMF, the modelled loop decodes 6245 off the
line, and the call comes up. Then the line goes silent and the answering modem
times out.
The datapump is not going quiet. It never starts. This is the chain that stops
it, read out of IDSDL302.ROM with the run's own counters, and it ends at one
event code.
Everything here is 302. main211.xmf is not fully modelled and its runs are
not evidence about the board; the gate the bridge currently uses came from a 211
run and is the first thing below that turns out to be wrong.
What the run shows
./courier run IDSDL302.ROM --with-dsp --exchange --exchange-number 6245=answer \
--tick-ms 5 --board-id 7 --nvram-fixture idsdl302 --at 'ATDT6245' \
--instructions 150000000
| observation | value |
|---|---|
| digits decoded off the line | dialed: "6245" |
| ASIC registers written | 13,15,16,17,19,1a,1b,1c,1d,1f,83 - no 82 |
control_82 |
0 |
commit_edges |
0 (all six 001f messages carry data 0000) |
call_overlay_available / call_overlay_active |
true / false |
| DSP downloads | bootstraps: 1, 55,424 bytes - the resident bank only |
datapump dispatch (10/11) |
never sent |
The bridge arms the call only on asic_registers[0x82] == 0x00A0
(bridge.py _maybe_start_asic_call_engine), with a
fallback on a 0x1f zero-to-bit-15 commit edge. 302 sends neither, so
_v8_armed stays false, _resume_armed_call never runs, and
_activate_call_overlay is never called. The C52 keeps running its resident
bank, which holds the DTMF oscillator and no data modulation.
302 does arm its datapump - through the mailbox
After the last digit the supervisor drains a queued batch. The queue is a ring
at 0x29e..0x2ce, head [0x29a], tail [0x29c]; the drain at 0x8f521
streams (tag, data) pairs out 0x58/0x5a and 0x5c/0x5e, and 0x8f688
enqueues one message as three words.
001a:32d6 0044:003f 0048:7fff 0051:21ff 0052:1ef8 001c:0008 001d:0014
002a:0006 0042:0fd1 0049:8bf5 0050:{00c1,0145,0213,0310,040d,0500}
0053:000f 0071:0003 0077:0000 0076:0000 then 0017:704d
All of it inside 57.83M-58.07M instructions, 11,264 apart - a table walk,
immediately after the last digit at 54.59M. So the datapump is configured. What
never follows is the dispatch: datapump-slots.md has the
nine-slot table selected by mailbox commands 10 and 11, and neither appears
in the run.
The gate, in five links
1. The dispatch site is 0x8bee8.
8bee8 mov ax, 5a
8beeb call 8b863 ; -> CF
8beee jb 8bef8 ; CF set: send 5a instead
8bef0 call 8b84f ; -> ZF
8bef3 je 8bf01 ; ZF set: send nothing
8bef5 mov ax, 10 ; the datapump dispatch
8bef8 mov bx, [0x281]
8befc lcall 8f43:0224 ; enqueue
0x8bf05 is the same shape one branch over and sends tag 0x17 when the same
test comes back equal. The run emits 0017:704d, so that is the branch it
took.
2. 0x8b84f is the discriminator. It returns not-equal - dispatch 10 -
if any one of three flags is set:
8b84f test byte [0xa96], 2
8b856 test byte [0x5a5], 1
8b85d test byte [0x685], 1
In the run all three are zero: supervisor_call_cells reports 0a96: 0, and
nothing has set the others.
3. [0x685] |= 1 happens at exactly one place, 0x876c5, reached from
0x876b1 when [0x33e] & 4 == 0. The run has 033e: 2, so that branch would
be taken - if 0x876b1 were reached at all.
4. 0x876b1 is entry 1 of a far-call thunk table at 0x875d8 - nine
four-byte call near/retf stubs, 0x875d8 + 4n.
5. The only thing that reaches it is an indexed jump on an event code.
a6ad7 jmp word ptr cs:[bx + 0x1dbe] ; bx = 2 * AL, CS = a4d2
The table at 0xa6ade is nine entries, AL = 0..8, each a far call into the
thunk table:
| AL | thunk | handler |
|---|---|---|
| 0 | 875d8 |
875f8 |
| 1 | 875dc |
**876b1 - sets `[0x685] |
| 2 | - | stc/ret, rejected |
| 3 | 875e0 |
876d5 |
| 4-8 | 875e4-875f4 |
876f2, 876f9, 87700, 87715, 87738 |
So the whole chain reduces to one thing: the datapump dispatch is armed by
call-progress event AL = 1, and nothing in the run delivers it.
Measured: the router never runs, and AL is not an event code
--trace-pc ADDR[=NAME] records the 80186's registers each time an address
executes. Running the dial with a watch on every link:
./courier run IDSDL302.ROM --with-dsp --exchange --exchange-number 6245=answer \
--tick-ms 5 --board-id 7 --nvram-fixture idsdl302 --at 'ATDT6245' \
--instructions 150000000 --summary \
--trace-pc a6ad7=router-jmp --trace-pc 8b84f=discriminator \
--trace-pc 8bee8=dispatch-site --trace-pc 8bef5=send-10 \
--trace-pc 8bf05=send-17-site --trace-pc 876c5=set-685-bit0
| watch | hits |
|---|---|
queue-drain 8f521 |
45 |
discriminator 8b84f |
19 |
dispatch-site 8bee8 |
1 |
send-17-site 8bf05 |
1 |
send-10 8bef5 |
0 |
router-jmp a6ad7 |
0 |
router-entry a6a7a, entry1 876b1, set-685-bit0 876c5 |
0 |
The one pass through the dispatch site is the whole story, and it runs exactly as read:
@59,801,686 8bee8 ax=02b2 ; enter, mov ax,5a
@59,801,696 8b84f ax=005a flags=0296 ; ZF set -> je 8bf01, nothing sent
@59,801,899 8bf05 ax=0019 ; the other branch
@59,801,908 8b84f ax=0019 flags=0296 ; ZF set -> falls through to mov ax,17
which is the 0017:704d the run emits. mov ax, 10 is never executed.
And the router is never entered at all. Its real entry is 0xa6a6c, which
begins:
a6a6c lcall 8000:9cbc ; AL <- parsed number
a6a71 jb a6adc
a6a73 test byte [0xea7], 1
a6a78 je a6a84 ; [0xea7]=0 here, so AL==1 is *not* rejected
a6a7a cmp al, 1
0x89cbc is a decimal ASCII string parser - lodsb, sub al, 0x30,
mov ah, 0xa, mul ah, accumulate. So AL is a number parsed out of a
command string, not a call-progress event code. An earlier revision of this
document called it an event code; that was wrong, and the trace is what
corrected it. 0xa6a6c is one of a table of command handlers whose offsets sit
at 0xa6615-0xa6631.
That changes what the blocker is. [0x685] |= 1 - the one of the three flags
with any reachable setter at all - is set on a command path, not by the
board reporting progress. Of the other two: [0x5a5] bit 0 has no setter
anywhere in the image (only and [0x5a5], 0xfe at 882db and 8982e clear
it), and there is no or [0xa96], 2 either.
Where it actually stops: the overlay is never requested
Tracing further up found the real end of the chain, and it is not the 0x10
message at all.
The C52 gets a datapump by the supervisor downloading one.
dsp-overlays.md has the map - overlays 6, 7 and 8 in flash,
loaded into program space at 9d00, b000 and dc00. The loader is at
0x8e5da:
8e5da mov al, [0xe3c] ; the overlay id
8e5df cmp al, 6
8e5e3 call 8e5eb ; id 6 loads first, then
8e5e6 mov byte [0xe3c], 8 ; ...switches to 8
8e5eb mov al, [0xe3c]
8e5ef and ax, 0xf
8e5f2 mov bl, 6 ; mul bl ; mov bx, e711 ; add bx, ax ; index the table
8e5fb mov ax, cs:[bx+4] ; the C52 load address
8e601 mov al, 4
8e603 out 0x1e, al ; start the transfer
8e61c in al, 0x1e ; poll for bit 2
That is exactly the transport the bridge already models for the resident
bootstrap. It is called from the post-dial sequencer at 0x8b5d1, and only
when [0xe3c] is non-zero:
8b5ca cmp byte [0xe3c], 0
8b5cf je 8b5d4
8b5d1 call 8e5da ; download the overlay
Measured:
| watch | hits |
|---|---|
loader-gate 8b5ca |
1 |
call-loader 8b5d1 |
0 |
overlay-loader-entry 8e5da, out-1e-cmd4 8e603, poll-1e 8e61c |
0 |
[0xe3c] is zero, so no overlay is ever requested. That is why the run reports
bootstraps: 1: the resident bank and nothing else.
One gate explains all of it
[0xe3c] is set to 6 or 7 by the selection code at 0x8bbaa-0x8bc4d, and
that code is guarded by the same discriminator as the 0x10 dispatch:
8bbaa call 8b863 ; CF gate
8bbad jae 8bbc2
8bbba mov byte [0xe3c], 6
8bbc2 call 8b84f ; the discriminator
8bbc5 jne 8bbca
8bbc7 jmp 8bc52 ; equal -> skip every [0xe3c] assignment
The run reaches 0x8bc52 - it emits the 001c:0008 that the code just past it
sends - having skipped all of them. So 0x8b84f returning equal is the single
root cause of both symptoms: no overlay downloaded, and no 0x10 dispatched.
It returns equal because [0xa96]&2, [0x5a5]&1 and [0x685]&1 are all zero,
and the only reachable setter for any of them is in the thunk cluster at
0x876b1/0x87752, reached only from the jump table at 0xa6ade, reached only
from 0xa6a6c - a command handler whose command this run never issues.
The profile hypothesis, tested and not supported
The previous revision guessed that the three flags were profile settings
restored from NVRAM, and that --nvram-fixture idsdl302 being sparse was the
gap. The settings diff is real, and the hypothesis is still wrong.
The fixture is a blank EEPROM. idsl302_fixture seeds only words 94..102
and the +S block and leaves the rest erased, and the firmware renders exactly
that. ATI5 under the emulator against ATI5 on the 4.03d hardware:
| board | fixture | |
|---|---|---|
| switches | B0 F1 M1 X7 &A3 &B1 &G2 &H1 &I0 &K1 &L0 &M4 &N0 &P1 &R2 &S0 &T5 &U0 &X2 &Y1 %N6 |
B7 F0 M7 X0 &A3 &B7 &G7 &H7 &I15 &K7 &L3 &M15 &N3213 &P3 &R7 &S7 &T4 &U3213 &X7 &Y7 %N15 |
| S registers | S00=001 S07=060 S11=070 S27=048 S58=064 ... |
every one 255 |
| baud | 115200 | 110 |
But making the firmware load a real profile through its own command path does not move the gate:
| run | call-loader 8b5d1 |
|---|---|
--at 'ATDT6245' |
0 |
--at 'AT&F' --at 'ATDT6245' |
0 |
--parameter-sector with a serial and the V.34/V.90 feature bits |
0 |
AT&F loads the ROM defaults into the working profile - the profile the call
actually uses - so if the flags came from settings, that run would have set
them. It does not. The three flags are not profile-derived.
A separate gap: the parameter sector is absent
ATI7 on the hardware ends with a line the emulator does not print at all:
| field | board 4.03d | emulator, 302 + fixture |
|---|---|---|
| Product type | Russia (ex. US/Canada) External | US/Canada External |
| Supervisor rev | 7.4.16 | 7.3.14 |
| DSP rev | 3.1.2 | 3.0.13 |
| Serial Number | 0009540034268322 |
line absent |
The serial number lives in the parameter sector, not in NVRAM -
courier_emu/parameters.py, sector 0x11..0x1c to CPU 0x0a17..0x0a22 - and
none of the dial runs pass --parameter-sector or --parameter-flash, so the
store is simply not there. Supplying one restores the line. It does not affect
the datapump gate, so it is a real modelling gap on its own account rather than
the blocker.
The Options line is identical on both, so the unit's V.34/V.90 entitlement is
not what is refusing the overlay.
The cells, read off the hardware
The NVRAM driver sits at the same address on 302 and 403, and ID_SDL has a
read-only memory dump command - ATGLK2=<segment>:<offset>, the one
flash_dump.py already uses to capture the 512 KiB flash. That reads the gate
cells directly off the running board. --peek ADDR[=NAME] reports the same
cells from a run.
Sampled on the board at three points - as found, after ATZ, and while an
inbound call is being offered with S0=0 so the modem stays in command mode:
| sample | 685 |
5cd |
33e |
5a5 |
a96 |
e3c |
5fa |
600 |
ea7 |
|---|---|---|---|---|---|---|---|---|---|
| as found | ff |
e0 |
11 |
08 |
00 |
00 |
00 |
00 |
00 |
after ATZ |
ff |
e0 |
11 |
08 |
00 |
00 |
00 |
00 |
00 |
| while ringing | ff |
e0 |
11 |
08 |
00 |
00 |
00 |
00 |
00 |
Identical at all three. These are not call-progress state: nothing about offering the loop a call moves them, and a reset does not either. Whatever sets them is done before the DTE is first reachable.
Two corrections this forced
The emulator's RAM is 0xff-filled, not zeroed. Running the 403 capture
reads 685=ff, 5cd=ff, 5a5=ff, 5fa=ff, 600=ff where the 302 run reads 00.
So the 00s in a 302 run are the 302 image's own data initialisation, not a
missing write - and not, as the previous revision had it, "cells the emulator
never initialises". Watching all seven mov byte [0x685], 0 sites plus both
and [0x5a5], 0xfe sites across a full 302 dial gives zero hits on every
one: nothing clears them at runtime. They start at zero.
The addresses are 302-derived and the hardware is 403. 0x685, 0x5cd
and 0x33e were read out of a disassembly of IDSDL302.ROM, supervisor
7.3.14. The board runs 7.4.16, where the same variables need not live at the
same addresses. The hardware column above is therefore only comparable to a 302
run if the data layout is unchanged between the two builds, which is not
established. The previous revision's hardware-versus-emulator table did not
state this and overreached.
The 403 capture cannot settle it yet: run in the emulator it does not dial at
all - dialed: "", call-loader zero hits - so its cells are simply
uninitialised rather than a comparison. Making the 403 image dial is the
prerequisite for any cell-level comparison against this board, and it is the
next thing worth doing, both because it is the firmware the hardware actually
runs and because without it there is no apples-to-apples reading.
Why the 403 capture does not dial
It is not the supervisor. Run side by side, 302 and 403 do the same things up to the point where sound should appear:
302 (IDSDL302.ROM) |
403 (board capture) | |
|---|---|---|
| bootstrap | match, 1 download | match, 1 download |
| hook / line | off hook, dial tone qualified | off hook, dial tone qualified |
| keypad messages sent | 0013:0006 0002 0004 0005 |
the same four |
0016:0000 |
8 | 8 |
| host messages / DSP took | 68 / 385 | 70 / 377 |
| datapump transmit | DTMF bursts, peak ~22,700 | 66,251 samples, peak 0 |
| exchange decoded | 6245 |
"" |
The 403 supervisor dials. Its DSP puts pure silence on the line.
And the DSP is not broken, because the same image's tone code works when it is
driven directly. courier_emu.audio312 on that very ROM renders one digit
through the firmware's own selector, oscillator, mixer and serial ISR:
.venv/bin/python -m courier_emu.audio312 \
--rom artifacts/courier-board-21210-capture-403/courier-board.rom \
--digits 6 --output /tmp/one
peak 21,516, row 770, column 1477 - a clean 6. So the oscillator, the mixer
and the ISR all work under 3.1.2. What does not happen in the full-board run is
whatever should arm them when the mailbox carries tag 0x13.
That is a known divergence between the two DSP builds rather than a surprise:
driving-the-tones.md records tag 0x13's handler at
0xd82f in 3.0.13, while in 3.1.2 13 enters 0xee20. 302 carries 3.0.13 and
the board carries 3.1.2, which is exactly the pair that differs here.
ee20 runs, and it arms the oscillator correctly
The C52's trace window used to be two hardcoded ranges. set_pc_trace_range
adds a third, settable one - --dsp-trace-range FIRST:LAST - and pointed at
ee00:ef00 it catches the handler four times in a dial, once per digit:
ee20 ldp #007
ee21 lamm @7a ; the keypad index the supervisor sent
ee22 and #0f ; low nibble
ee24 sfl ; x2, two words per entry
ee25 add #ee34 ; the frequency table
ee27 tblr @74 ; column increment -> 3f4
ee29 tblr @72 ; row increment -> 3f2
ee2a splk @1a, #8743 ; the DTMF-pair callback, into 39a
ee2e splk @73, #1000 ; amplitude -> 3f3
ee31 sacl @40 / @41 ; clear both phases
ee33 ret
Every cell it touches is one answer-tone.md already named:
3f2/3f3/3c0 for the first oscillator, 3f4/3f5/3c1 for the second,
and 39a for the mixer's callback slot. 8743 is precisely the pair
generator. So the handler is not the fault: it runs, per digit, and arms the
tone the way the firmware intends.
The generator runs. The silence is after it.
--dsp-write-watch ADDR records every write to one C52 data cell with the
program address that made it. The core's write trace existed but was
unfiltered, and its 4096-event buffer covers a few milliseconds of a run; the
read side also traces a fixed set of cells, which floods the buffer on its own.
Both now honour the filter.
Watching 39a, the mixer's callback slot, across a 403 dial:
ee2b 8743 @51,371,302 digit 1: the handler arms the pair generator
86dc 8128 @53,720,889 ...and 86dc restores 8128
ee2b 8743 @55,664,990 digit 2
86dc 8128 @58,016,770
ee2b 8743 @59,959,466 digit 3
86dc 8128 @62,310,745
ee2b 8743 @64,253,460 digit 4
86dc 8128 @66,604,900
Four arm/restore pairs, one per digit, about 2.3M instructions apart - roughly
the tone's own duration. That is a one-shot callback lifetime, not the clobber
the end-of-run value suggested; 8128 is simply what the slot holds when no
tone is playing, and reading it after the run was reading the idle state.
And the generator really runs in between. Watching 3c0, the first
oscillator's phase, inside the last window:
8753 48d5 @66,442,944
8753 7856 @66,445,517
8753 a7d7 @66,448,001
8753 d758 @66,450,565
+0x2f81 per sample, which is exactly the row increment tblr loaded into
3f2. The oscillator is advancing at the right rate, from the right table
entry, driven by the firmware's own code.
The signal reaches the mixer's accumulator and dies before DXR
The write trace keeps the last 64 events, and both 3c7 and DXR are written
every sample, so a full-length run only ever shows the idle tail. Ending the
run inside the first digit instead - --instructions 47500000, which lands at
DSP instruction 52.6M, inside the first 8743 window - catches the tone
itself.
The mixer's accumulator carries the tone. Writes to 3c7 in that window:
875b edd2 874e ... 80d6 0000
875b 35e3 (once per frame, the calad delay slot)
875b 3028
875b e4e7
875b c0c5
874e and 875b are the two sach @47, 3 in the pair generator, and the
values are a waveform. Reading the callback confirms the shape: 8743 loads
the column increment, calls the sine table at 8b6a, advances the phase at
41, multiplies by the amplitude at 75, accumulates into 47, then falls
through to 874f which does the same for the row. 8128 - what the slot holds
when idle - is a bare ret.
And DXR is zero at the same instant. Watching MMR 0x21 over the same
window:
818f 0000 @dsp 52,674,534
818f 0000 @dsp 52,677,095
818f 0000 @dsp 52,679,656
818f 0000 @dsp 52,682,222
Same run, overlapping instruction counts: 3c7 live, DXR zero.
So every stage from the mailbox to the mixer's accumulator is correct - the handler arms, the oscillator advances at the loaded increment, the callback accumulates a waveform - and the signal is lost in the stage after it. That leaves about ten instructions:
80da lt @47 ; the accumulator the callback just filled
80db mpy @12 ; times the gain at 392
80dc pac
80dd bit 5, @1f
80de add16 @7b
80df cc c4e9, tc
80e1 and #7ffe0000
80e3 mar *, ar7
80e4 bd 80c3, *
80e6 mar *+
80e7 sach *+, 1 ; the store into the transmit buffer
and its relationship with the ISR. Both were checked, and neither is at fault.
The buffer and the work pointer are correct
Watching 390 inside the tone shows a clean circular buffer, written only by
the ISR at 8190:
8190 0bca -> 0bcc -> 0bce -> 0bd0 -> ... -> 0bde -> 0bc0 -> 0bc2
Sixteen slots, 0bc0..0bde, step two, wrapping. Even slots are receive - the
ISR's sacl *+ at 8183 - and odd slots are transmit, which the mixer fills
with sach *+, 1 at 80e7 and the ISR reads back through or *+ at 818e.
The two ends agree.
Watching the slots themselves in the same window:
0bc1 80e7 0000 the mixer's store, into a transmit slot
0bc0 8183 0000 the ISR's receive store
So the mixer does reach its store, on the right slot, and writes zero.
The gain is zero
--dsp-peek inside the tone, against a 302 run inside its own first digit:
| cell | 302, audible | 403, silent |
|---|---|---|
39a mixer callback |
874e |
8743 |
3c7 accumulator |
f5db |
3fd1 |
3f3 amplitude |
1000 |
1000 |
392 gain |
32c8 |
0000 |
3f1 |
0c08 |
0000 |
3f5 second amplitude |
0c08 |
0000 |
80db is mpy @12 - the accumulator times 392. On 403 that multiplier is
zero, so the product is zero and sach *+, 1 stores silence. Everything
upstream is live; the tone is multiplied by nothing.
And the two zero cells are exactly the two the supervisor sends. Its dial block
carries 001a:32c8 and 001b:0c08, and
driving-the-tones.md has their destinations as DSP data
0392 and 03f1. On 302 those cells hold precisely 32c8 and 0c08. On 403
they hold nothing; 3f5 is zero because the handler at ee2c copies 3f1
into it.
3.1.2 puts them exactly where they belong
The dispatcher vectors through a 128-entry table at program 83e9, and the
table validates on its own: entry 0x13 is ee20, the handler already watched
running. Reading the two in question out of the 403 image:
8227 smmr @7a, #03ad ; tag 19
822a smmr @7a, #0392 ; tag 1a
822c smmr @7a, #fff0
8232 smmr @7a, #03f1 ; tag 1b
0392 and 03f1 - precisely the destinations
driving-the-tones.md records. 3.1.2 does not move
them, and the guess in the previous revision that it might was wrong.
(The same table read against 302 is meaningless: its entry for 0x13 comes out
as 8179, which is inside the serial ISR. The table's address is 3.1.2's, so
3.0.13's handlers are elsewhere and none of the 302 column can be trusted.)
The handlers run, and store zero
Every write to 0392 across a 403 dial:
801d 0000 @dsp 284,014 boot
807f 32d6 @dsp 284,854
... six such pairs through 40.6M ...
822b 0000 @dsp 51,286,031 tag 1a, just before digit 1 arms at 51,371,302
822b 0000 @dsp 55,566,786 digit 2
822b 0000 @dsp 59,861,340 digit 3
822b 0000 @dsp 64,154,570 digit 4
822b 2fd6 @dsp 68,309,089 after the dial
822b 2fd6 @dsp 68,448,105
The handler fires once per digit, each time a few tens of thousands of
instructions before that digit's ee20 arms the oscillator - exactly the
ordering the supervisor's block implies. And each time it stores zero.
So the handler is right, the destination is right, and the value is wrong.
The delivered word is zero
The dispatcher itself is faithful. 8387 reads three cells through the helper
at 80e8 (lamm *, ret):
8393 lar ar1, #57 ; status - bit 15 is "message pending"
8399 lar ar1, #5e ; the tag -> 7d
8399 lar ar1, #5f ; the data -> 7a (sacl @7a at 839b)
839f sub #7f
83a1 add #00008468 ; tag - 7f + 8468 == tag + 83e9, the table read above
57, 5e, 5f are exactly HOST_STATUS_CELL, HOST_TAG_CELL and
HOST_WORD_CELL in bridge.py. Nothing is misaddressed.
Watching 7a - the cell 839b fills - around the first digit:
839b 0000 @dsp 51,286,021
822b 0000 @dsp 51,286,031 tag 1a stores it into 0392, ten instructions later
839b 0000 @dsp 51,314,394
839b 0006 @dsp 51,371,284
ee20 ... @dsp 51,371,302 tag 13 arms the oscillator with the right digit
So the word delivered alongside tag 0x1a is zero, and the handler stores
exactly what it was given. The supervisor's own message stream records
001a:32c8. Between the supervisor writing that message and the DSP reading
it, the data word is lost, while the tag survives - the correct handler runs -
and a small value like 0006 survives intact.
That is this emulator's host-message delivery, not the firmware. 0x13 working
while 0x1a does not is what makes it worth chasing rather than a dead path.
(An earlier reading of this trace pointed at three mangled-looking words -
0032, c802, 0400 - as the corrupted 32c8. They are at DSP 40.6M, and
the tag 0x1a handler does not run until 51.28M, so they belong to other tags
and are not evidence of anything here.)
The two delivery paths, diffed
There are not two competing writers. _mirror_port is unreachable for the
mailbox ports: the runtime-port branch in io_write returns before the
asic_transparent mirror is reached, so MIRROR's 0x5C -> (0x5F, 0) and
0x5E -> (0x5F, 1) never fire for 0x58/0x5A/0x5C/0x5E. One writer
reaches the DSP's host cells: _deliver_host_message.
What differs is when each path acts on the message:
| assembly | delivery | |
|---|---|---|
| trigger | each port write; the message is recorded on the 0x5E write, the data's high byte |
the supervisor's 0x1C bit 0, in the boot_rom_enabled branch |
| state | one latch pair, _runtime_header / _runtime_data |
reads that same latch, whatever it holds at that instant |
The two are decoupled, and the run says so out loud:
| messages assembled | delivered to the DSP | |
|---|---|---|
| 403 | 68 | 70 |
| 302 | 66 | 68 |
Two more deliveries than there were messages, on both images. A 0x1C
acknowledgement that arrives when no new message has been assembled
re-delivers the stale latch.
The same decoupling explains the zero. _runtime_header is updated by the
0x58/0x5A writes and _runtime_data by 0x5C/0x5E, so between those two
pairs the latch holds a new tag with the previous message's data. A 0x1C
bit 0 in that gap delivers exactly that. And the previous message is
0016:0000 - the dial block's own start marker, which the run sends eight
times - so the stale data is 0000, which is what 839b read and 822b
stored into the gain.
Delivery should be triggered by message completion, the same 0x5E write that
records it, rather than by an acknowledgement that can land mid-message. That
is a bridge change and wants its own measurement afterwards: the assembled and
delivered counts should agree, 0392 should take 32c8, and the 403 image
should put a tone on the line.
The fix, and what it did not fix
Delivery now holds the completed pair. The 0x5E write - the message's last
byte - latches _runtime_pending, and the 0x1C bit 0 commit delivers that
pair and clears it, so a repeated acknowledgement cannot re-send the last
message and a commit landing mid-assembly cannot send a half-updated latch.
| assembled | delivered before | delivered after | |
|---|---|---|---|
| 403 | 68 | 70 | 68 |
| 302 | 66 | 68 | 66 |
302 is unaffected in behaviour: still dialed: "6245", still a tone at peak
22,764, still reaching ringback.
The tone checks still fail, and the reason is that the premise was wrong. 403 is not being handed a corrupted gain. Its supervisor genuinely sends zero:
| tag | 302 sends | 403 sends |
|---|---|---|
0019 |
020d x7 |
c802 x6, 0400 x1 |
001a |
32c8 x4, 32d6 x2 |
0000 x4, 2fd6 x2 |
001b |
0c08 x4 |
0000 x4 |
001f |
0000 x6 |
0032 x6 |
The 32c8 attributed to 403 in the previous revision was read off a 302
run. The DSP receives exactly what its supervisor sends, 822b stores exactly
what it receives, and the gain is zero because 7.4.16 sent zero. Every claim
here that the delivery path corrupted a value was wrong.
So the question moves up one level again: why does 7.4.16 compute zero for the
tone's gain where 7.3.14 computes 32c8. The whole register block differs, and
the 403 values are suggestive - c802, 0032, 040b against 302's 020d,
32c8, 0c08 - which looks like the same bytes read at a one-byte offset.
Whether that is 7.4.16 reading its own parameter table differently or this
emulator feeding it a misaligned one is the next question, and it is
answerable: the supervisor assembles these into the ring at 29e before the
drain at 8f521 sends them, so watching the 80186 write that ring says which.
The supervisor enqueues the zero itself
--mem-watch FIRST:LAST records 80186 memory writes in a range with the
program address that made each. The first attempt watched 29e..2cd on both
images and looked like a smoking gun - 302 filled by 8f678 with clean
three-word messages, 403 apparently scribbled over by a dozen unrelated PCs:
302 [02aa] 001a [02ac] 32c8 [02ae] ff00
[02b0] 001b [02b2] 0c08
403 [029f] 0002 [02a0] 00f4 [02a7] 0e00 [02b7] 0001 ...
That was another 302-derived address. 403's drain reads its pointer from
[0x194] and wraps at 0x1c8, not [0x29a]/0x2ce, so 29e on 403 is
unrelated memory and the "scribble" is just other variables.
Watching 403's own ring shows its enqueue at 8f668 writing this:
[01ba] ff00 the marker
[01bc] 001a the tag
[01be] 0000 the data
[01c0] ff00
[01c2] 001b
[01c4] 0000
The supervisor enqueues zero. The ring is correct, the drain is correct,
the delivery is correct, the dispatcher is correct, the handler is correct and
the oscillator is correct. 7.4.16 computes zero for the tone's gain and second
amplitude where 7.3.14 computes 32c8 and 0c08, and every stage after that
faithfully carries the zero to mpy @12.
Nothing in the emulator corrupts these values, and the several revisions of
this document that said otherwise were each wrong for the same reason: an
address read off the 302 disassembly and applied to a 403 run. 29a against
194, and before that the cell addresses in the hardware comparison. On this
pair of images an address is only meaningful with its image named.
Where the 403 zero comes from
The gain is not computed. It is read straight out of two RAM cells:
a0ab1 mov bx, word ptr [0x0cd9] ; mov ax, 001a ; lcall 8f46:01e4
a0ac4 mov bx, word ptr [0x0cdb] ; mov ax, 001b ; lcall 8f46:01e4
Traced across a dial, each fires exactly once, with bx = 0000, and
--peek reads both cells as zero. The far call goes through the thunk at
8f644, whose CS is 8f46 - which is why the caller's return address only
resolves with that segment, not the 8000 the rest of the supervisor runs in.
Nothing in the image writes either cell by absolute address. The only two
references are those reads. The neighbouring cells in the same block are
populated - [0xca7] is 55 and [0xcf9] is 32, and 0x8bfc9 sends that
32 as tag 001f - and they are filled by the byte copy at a0907, which
walks a CS-relative table selected by [0x0c9e]:
a0907 mov di, 0ca7
mov bx, [0c9e] ; 0d40 in this run, with CS 9efe
mov al, byte ptr cs:[bx]
mov byte ptr [di], al
So the source table is at physical 9fd20, and the copy runs twice. But
watching every write into 0cd8..0cdc across the run shows it never touches
them: the only writers are fd229 at boot, 804c6 clearing the region, and
80822/80828 writing 5555/aaaa, which is a RAM test. 0cd9 and 0cdb
sit past the end of what the copy fills, and nothing else fills them.
That is as far as static reading goes. The question it leaves is whether those
cells are also zero on the hardware - in which case 7.4.16 does something else
entirely for the transmit level and this whole path is a red herring - or
whether a real boot puts something there that this emulator does not. The board
runs this exact image, so ATGLK2=0000:0cd9 answers it directly. It was
unplugged when this was written; that read is the next step and needs nothing
else.
What is not established
Which command sets those flags, and what writes them on a real boot. The
handler table at 0xa6615 is never indexed by any jmp cs:[bx+...] in the
image, and no far pointer targets a4d2:1d4c.
The supervisor's real dispatcher, for the record
0x8f564 is call word ptr [0x298] - an indirect call through the current
state handler, with a selector in AL. It is the supervisor's event dispatcher,
and across a whole dial it runs three times:
| instruction | AL | result |
|---|---|---|
| 5,847,937 | 83 |
the first 0083:0083 |
| 35,662,523 | 83 |
the second |
| 59,801,997 | 82 |
BX=704d, the 0017:704d the run emits |
So 0x82 on 302 is an internal state selector, not an ASIC register write.
The bridge waits for asic_registers[0x82] == 0x00A0, which is main211's