Cryan209andClaude Opus 5 a97f71f288 The originate early return fires zero times; the pair stops at different times
Instrumented every branch of _service_line. originate_return is 0 on both
ends, so the guard proposed in the previous commit is exonerated - that
inference was wrong.

What the counters show instead: A calls _service_line_frame 228 times and
only 158 reach the peer, with line.connected False and "the far end closed
the line". The missing 70 frames are exactly 7.00 s, the shortfall measured
before and misexplained as an unshipped tail. A's buffer ends with 126
samples in it, so nothing was stuck.

Both ends stop at 85M x86 instructions, which is 22.82 s of codec time on A
and 15.89 s on B - a 44% divergence in instruction-to-sample ratio. B exits
first and A talks to a closed socket. The answer tone lands at 12.03-15.01 s,
so every nonzero sample A produces is generated after B has gone, which is
why a-tx is silent end to end rather than merely late.

Harness fault, not firmware. A linked pair budgeted on instructions gives the
two ends different clocks on a shared wire.