`65` and `db` were stopping two of the flash captures, and neither is a missing instruction. `65` is the 386's GS prefix and is undefined on this part. The 80C186EB manual says what the CPU does with one: "Execution of an undefined opcode causes an Invalid Opcode trap" (Type 6). That trap has a handler waiting for it - the Australian captures install a stub at 8000:0f83 that loads a fault code and jumps to the common reporter - so the faithful model is to vector it, not to end the run. 0f, 63, 64, 66, 67, d6 and f1 are undefined on the 186 for the same reason and take the same path; the 386ex profile keeps them. `db` is ESC, a real encoding. Whether it faults depends on RELREG's ET bit, which resets to zero and which nothing in these firmwares sets, so on this 16-bit part it goes out to an 80C187 instead. There is no 80C187 on the board, so the operand cycle is read and execution carries on. ET is modelled as a flag and takes the Type 7 path when set, which is what the 8-bit 80C188 would always do. A trap restarts its instruction rather than resuming past it, so it cannot go out as a software interrupt: `Uc.fault` marks which it is and the machine dispatches it with the faulting address. A fault is also not a controller request, so it stays out of the EOI stack that a hardware interrupt enters. Going past those two exposed the next stop, which was a real gap rather than a fault: SAHF, LAHF, INT3, INTO, WAIT, DAS, AAA, AAS and 82 as the documented alias of 80 are all defined 80186 instructions that were simply missing. They are implemented, and the line is kept deliberately - BOUND and INS/OUTS are still absent and still raise, because a gap in the model must not be swallowed by a trap that would hide it. Both 20.16 MHz captures now run a 60,000,000 instruction boot without error where they used to stop at about 6.2M. Neither reaches its ATI7: the divergence that sent them there is upstream of any opcode. In both, the last instruction fetched from flash is the `cb` ending the routine at 9e8cb, and that far return lands two bytes before the entry its own caller targets (`9a 39 07 00 80`, CALL FAR 8000:0739, against a return to 7ff8:07b7). One board then decodes a misaligned stream and the other runs into cleared RAM. That is the thing to chase next. The 2806's boot is byte-identical and still prints its profile, and the three XMF images are identical against a matched baseline. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>