Cryan209andClaude Opus 5 94b21e3a90 Carry the call-state mailbox measurement into the harness
The port table held one state and called it idle, with a docstring admitting
everything in it was sampled on hook. It now carries the three states the
board has actually shown, and says what 0x58 is: a latch of the last tag the
DSP published, which is why it reads 0x31 after query 07, 0x69 after 62,
0x44 once a call has ended and 0x20 while one is up. 0x60 reads 0x0a against
0x61 the same way.

The idle capture replays through the booted DSP and matches step for step,
the 07-62-07 alternation included, which the earlier capture never ordered
that way. The online capture does not match, and the report says so rather
than smoothing it: a harness with no call publishes the reply a real board
withholds. Why the board withholds it is unmeasured - the sender may be the
datapump's, or the completion may never be serviced - so that half is a
comparison and not yet a model.