Slot 0 of the datapump table is overlay 6's entry 9d00, and nothing here had ever run it: the DSP download carries only the resident bank, so 9d00 held resident words and the V.34 image stayed in flash. courier_emu.v34 publishes the overlay and enters it the way the firmware does, which took three corrections. The dispatcher's splk @7c and add @7c straddle an ldp #000, so it must be entered on page 0. 9b2c overwrites @27, so the mode flag cannot be preset. And @27 is built from a descriptor list at data fea1 that d665 walks with ARP 1 - #0045 is the word that yields @27 = 2, slot 0. Both sides then enter 9d00, run ~2,240 instructions, return, and install callbacks aafb and 9daf. The entry writes #4042 to @6f, which is the value fsk-modulation.md read off it statically before anything ran. No tone yet: the transmit chain runs and advances itself, but overlay 6 touches no converter and the mixer buffer stays zero, which is what a modulator with no start-up state and no data source should do. The test pins both the advance and the silence. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
8.8 KiB
Nine modulations, four images, and where fax lives
fsk-modulation.md found a nine-slot datapump table that
mailbox commands 10 and 11 dispatch through, and named two of its slots by
measuring them. This names the rest, accounts for the images they live in, and
follows the two things that are not in that table: the PCM downstream layer
and the fax modulations.
The modem's own list
The firmware carries its answer in plain text. AT*C transmits a constant
carrier, and its help text at 0x19f5a enumerates every carrier the modem can
produce - 76 of them, two per modulation per rate, one for each side:
(0) Bell 103, 300 (8) V.23 Forward Channel (26) HST 48
(2) V.21 (9) V.23 Backward Channel (32) HST 375 bps Back Channel
(4) V.22 (10) V.32 48 (34) V.FC 96
(6) V.22bis ... V.32 up to 216 (52) V.34 24 ... 288
courier_emu.datapumps.carrier_families reads it: Bell 103, V.21, V.22,
V.22bis, V.23, V.32, HST, V.FC, V.34. Nine families, slowest first - and the
datapump table is the same nine in reverse.
The slots
Flags are bit numbers; the BIT instructions that test them carry bit
codes, and the C5x shifts by ~code & 0xf, so code 14 is bit 1.
| slot | flag | table 9b48 (originate) |
table 9b51 (answer) |
modulation |
|---|---|---|---|---|
| 0 | @27 bit 1 |
9d00 |
9d00 |
V.34 |
| 1 | @26 bit 4 |
b000 |
b000 |
V.FC |
| 2 | @27 bit 3 |
b052 |
b052 |
V.32 / V.32bis |
| 3 | @26 bit 5 |
c533 |
c7fd |
HST |
| 4 | @26 bit 3 |
cd61 |
cce0 |
V.22bis |
| 5 | @26 bit 2 |
cd79 |
ccfa |
V.22 (with Bell 212A) |
| 6 | @27 bit 10 |
da31 |
d9bc |
V.23 |
| 7 | @27 bit 12 |
d808 |
d7fc |
V.21 |
| 8 | @26 bit 6 |
d7e9 |
d7d8 |
Bell 103 |
The order is the menu's, fastest first, which is what a rate-negotiation fallback ladder looks like. Six of the nine are held up by something measured rather than by the ordering alone:
- V.34 and V.FC. The two overlay predicates gate on S56 bits
0x40and0x80, which the modem's own help text namesV34andVFC- the firmware's label rather than an inference. See pcm-x2-v90.md. Independently,9d00selects codec rate index 5 - 8000 Hz for a 3429 baud symbol rate, which is V.34's alone and which no other slot asks for. See codec-sample-rates.md. - V.22bis and V.22. Both slots install the same transmitter
d34aand receiverce6e, differing only in a pointer to a 12-16 word parameter table. That transmitter steps a 12-entry carrier table by@44, which reads 2 on the originate entries and 4 on the answer ones: 1200 Hz and 2400 Hz at 7200, with@6cat 300 and 600 Hz. Two configurations of one 600-baud datapump is exactly V.22bis beside V.22/Bell 212A. - V.23. The two sides run different transmitters. Originate installs
db2d, which keys between increments0x2000and0x1bbc- a 13:15 ratio, which is 390/450 to five figures and matches no other standard pair. Answer installsdae0, which builds its increment from0x4aab, the 2100.0 Hz constant the answer tone uses, plus a data-driven term. Backward channel from the caller, forward channel from the answerer: V.23, and independent proof that table9b48is the originate side. - V.21 and Bell 103, measured in fsk-modulation.md.
Slot 0 has since been executed: see v34-arming.md.
Two rest on weaker evidence and are worth re-testing:
- V.32 for slot 2, whose region writes
@08=#4000= 1800.0 Hz at 7200. - HST for slot 3, on structure: its two sides have different transmitters
(
c9d2,c9a5), and of what is left HST is the asymmetric one - the menu lists 375 and 450 bps back channels for it.
That split is itself informative. Slots 0-2 carry the same entry in both tables; slots 3-8 are side-specific. Echo-cancelled full duplex (V.34, V.FC, V.32) needs no side in the entry; frequency-split or asymmetric modulations (HST, V.22, V.23, V.21, Bell 103) do.
Four images, and why 8 rides with 6
The loader settles the count. It masks the requested index to four bits and
compares against 6, 7 and 8, everything else falling through to the resident
segment; the row table at 0xe741 has rows 0-4 zeroed and rows past 8 are
garbage. Only 5, 6, 7 and 8 are ever written to the request byte 0x0d28.
One image is never requested by itself:
e60a mov al, [0xd28]
e60d and al, 0x7f
e60f cmp al, 6
e611 jne e61b
e613 call e61b ; load overlay 6...
e616 mov byte [0xd28], 8 ; ...then overlay 8 as well
So the sets are {6, 8} or {7} - and they cannot be otherwise, because
overlay 7 (b000-cd49) collides with overlay 6 (9d00-ce31) in program
memory while overlay 8 (dc00-f949) collides with neither.
courier_emu.datapumps.overlay_chain reports it.
Two predicates choose between them, at 0x8972 for 6 and 0x8999 for 7, each
gated on a disable bit in [0x4c6] (0x40 and 0x80) and a ceiling in
[0x4dd]. The DSP can also ask for an image itself:
in al, 0x5c ; or al, 0x80 ; mov [0xd28], al.
V.90 and x2 are overlay 8
Overlay 8 is the PCM downstream layer, and the chaining is the argument: it loads only alongside overlay 6, the V.34 core, which is what a PCM modem needs for its upstream. It takes no slot in the datapump table because it is not a modulation the modem transmits - it is a receiver for what the digital end sends.
The supervisor carries both rate ladders as CONNECT strings, in 1333⅓ bps
steps:
| rates | |
|---|---|
| x2 | 33333 … 57333, and 64000 - 16 rates, each also /ARQ/x2 |
| V.90 | 28000 … 62666, and 64000 - 28 rates, each also /ARQ/V90 |
x2 starts at 33333 where V.90 starts at 28000, and V.90 fills in every step between. How the two are enabled, what each hands the DSP, and what is still unknown about them is in pcm-x2-v90.md.
Fax is resident, and it collides with overlay 8
The AT*C menu has no fax entry - its own text says fax carriers need
AT+FCLASS=1+FATX=nn instead - and the fax commands are in a separate parser
table at 0x20d80, names then handler offsets: TS= RS= TM= RM= TH= RH= CLASS ATX= ARX= AA TXD= …, which is Class 1 (+FTM, +FRM, +FTH, +FRH) and
Class 2.0.
On the DSP side the fax modulations are in the resident bank, dispatched by
three mailbox tags whose handlers park a table base in @7d and jump to a
shared selector at dc8e that indexes it by the argument's high nibble:
| slot | tag 21 |
tag 22 |
tag 20 |
carrier | modulation |
|---|---|---|---|---|---|
| 1 | d853 |
d808 |
d864 |
1650/1850 | V.21 channel 2 (300 bps HDLC) |
| 2 | dc79 → e525/e532 |
dc59 |
ddbb |
1800 Hz | V.17 |
| 3 | dc75 → e4f6 |
dc55 |
dd96 |
1700 Hz | V.29 |
| 4 | dc71 → e4d5 |
dc51 |
dd78 |
1800 Hz | V.27ter |
| 5 | def0 |
def0 |
def0 |
- | none |
courier_emu.datapumps.fax_carriers follows each slot's branches to the
splk @44, #<increment> it installs and reads it at 7200 Hz. 1700 Hz is
V.29's carrier and nothing else's, which is what makes that row an
identification rather than an ordering argument; the two 1800 Hz rows are
told apart by the same descending-speed convention the data ladder uses, so
V.17 above V.27ter is inference, not measurement. Tag 21's slots install a
transmit carrier and tag 20's install receive coefficients instead, which is
what half duplex needs; slot 1 needs no carrier of its own because it reuses
the FSK modulator's cells through the V.21 setup routines.
The consequence is structural: the fax dispatch (dc48-dcf4) and its
datapumps (e4d5 onward) sit inside dc00-f949, which is exactly overlay
8's load range. Loading the PCM layer overwrites the fax subsystem, so a
V.90/x2 connection and Class 1 fax cannot be resident at the same time - the
board reloads for one or the other. The one part that survives is slot 1: the
V.21 channel 2 code is the same FSK datapump the data ladder uses, and it
sits below dc00.
What is still open
- Slot 2 = V.32 and slot 3 = HST rest on one constant and on structure. Both should be measurable the way V.22 and V.23 were, by bringing the entry up and reading its carrier cells.
- Nothing separates x2 from V.90 inside overlay 8 yet. Overlay 8 does hold
two code families, but the bit that forks them turned out to be
&X, the synchronous clock source - see pcm-x2-v90.md. - V.17 versus V.27ter for the two 1800 Hz fax rows is an ordering argument.
- The
+FTM/+FRMhandlers reach the mailbox through the supervisor's command ring rather than a direct call, so the mapping from a Class 1 modulation number to one of these five slots has not been read out of the supervisor.