mirror of
https://github.com/D-Modem/courier-emu.git
synced 2026-11-28 20:38:07 -08:00
The port table held one state and called it idle, with a docstring admitting everything in it was sampled on hook. It now carries the three states the board has actually shown, and says what 0x58 is: a latch of the last tag the DSP published, which is why it reads 0x31 after query 07, 0x69 after 62, 0x44 once a call has ended and 0x20 while one is up. 0x60 reads 0x0a against 0x61 the same way. The idle capture replays through the booted DSP and matches step for step, the 07-62-07 alternation included, which the earlier capture never ordered that way. The online capture does not match, and the report says so rather than smoothing it: a harness with no call publishes the reply a real board withholds. Why the board withholds it is unmeasured - the sender may be the datapump's, or the completion may never be serviced - so that half is a comparison and not yet a model. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>