Files
courier-emu/docs/feature-bits-audit.md
Claude c86443ce5e docs: audit of the Courier feature bits
Which builds read record 2, what each bit gates (ATI7, &N speed limit,
x2 in a call), the code that overrides the record (HST from the hardware
probe; x2 always on in 7.4.16 and 7.6.7), and who can write the record
(6.x: ATC only; 7.x: also the remote LAPM UI messages).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B82eRT9hoUA6h3xfALh3cS
2026-11-17 16:14:25 +00:00

6.4 KiB

Audit of the Courier feature bits

Written in ASD-STE100 Simplified Technical English.

This document gives the result of an audit of the feature record (record 2, ATC8) in the Courier supervisor firmware. It tells which bits have an effect, in which builds, and which builds let a host change them. D-Modem's x2 upgrade host (AT+X2UP) writes this record.

1. Images

The images came from firmware/legacy-usrobotics/ and from the board captures in artifacts/. tools/unpack_sdl.py made a flash image from each DOS flasher (SDL.EXE and others). The outer .EXE files are ZIP and ARJ self-extractors; 7z and unar open them. A DOS emulator is not necessary.

Supervisor Date Images Upgrade handler x2 at power on
6.2.0 to 6.5.4 05/94 to 09/96 13 flashers (SDL0196 ... SDL0920, V34PLUS, SDL_CS*) No Not present
7.1.4 02/25/97 courier-714-221-flash-20261007 Yes Record 2 bit 5
7.3.14 03/13/98 IDSDL302.ROM, courier-board-21210-capture-01, courier-2806-25mhz-flash-20260912 Yes Record 2 bit 5
7.4.16 04/30/98 SDL0430, SDL0430N, SV_49, courier-board-11430-flash-20260914-02 Yes Always on
7.6.7 12/02/98 V90SDL (SDL1202I), courier-board-11430-flash-20260914-unit2-02 Yes Always on
7.4.16, ID_SDL 4.01 to 4.03 04/30/98 ID20*, ID25*, courier-board-21210-capture-403 Yes Always on

The ID_SDL images are not U.S. Robotics firmware. They are "Extended USR SDL" by Igor Diagilev (Khabarovsk), and ATI7 shows "NOT For Sales". See the firmware lineage map. The strings of IDSDL302.ROM also name this author, but its feature code is the same as the stock 7.3.14 code.

2. From the record to the runtime byte

At power on, the supervisor decodes record 2 and sets bits in a runtime feature byte. The address of the byte changes with the build.

Build Power-on code Runtime byte
6.5.4 08b8 0871
7.1.4 0908 0893
7.3.14 08ea 089d
7.4.16 08f1 0791
7.6.7 08f3 0795

All builds use the same map:

Record 2 bit Value Feature Runtime bit
1 1 HST 04
2 2 Fax 08
3 4 Terbo (V.32terbo) 40
4 8 V.FC and V.34 80
5 16 x2 (and V.90 in builds that have it) 20

The 6.x builds do not read bit 5. No build reads bits 6, 7 or 8. Other code sets the runtime bits 01, 02 and 10; the record does not control them.

3. Code that overrides the record

These steps occur after the records are decoded:

  • HST. The supervisor sets runtime bit 04 (HST) when a hardware byte has neither bit 40 nor bit 80. The probe at 096f (7.1.4) sets this byte, not a record. The step is at 0549 (7.1.4), 052b (7.3.14) and 0532 (7.4.16, 7.6.7). Most 6.x builds from 11/95 have it too. Thus, on the board that was examined, HST is always on.
  • x2. Supervisor 7.4.16 and 7.6.7 set runtime bit 20 (x2) at 0519 with no condition. Thus, in these builds, record 2 bit 5 has no effect. 7.1.4 and 7.3.14 do not have this step.
  • ID_SDL. The ID_SDL builds also change the x2 test of the power-on code (091c) from 74 05 (je) to 90 90 (nop nop). This change has no effect, because of the step at 0519.

4. Effects that were measured

The emulator ran each image with an EEPROM from tools/feature_nvram.py (board ID 7, default DIP switches).

4.1 ATI7

Supervisor 7.3.14 (courier-board-21210-capture-01):

Record 2 Options line
0, 1, 2, 3 HST,V32bis
4, 7 HST,V32bis,Terbo
8, 9, 10 HST,V32bis,Terbo,VFC
12, 15 HST,V32bis,Terbo,VFC,V34+
16 HST,V32bis,x2,V90
24 HST,V32bis,Terbo,VFC,x2,V90
31 HST,V32bis,Terbo,VFC,V34+,x2,V90

7.1.4 gives the same lines for 0, 15 and 31, but without V90. V34+ needs bit 3 and bit 4. The fax line (Class 1,Class 2.0) and AT+FCLASS=? (0,1,2.0) did not change with bit 2.

Supervisor 7.4.16 and 7.6.7 show x2,V90 with record 2 set to 0.

4.2 Speed limit (&N)

Supervisor 7.3.14. The table gives the highest &N value that the Courier accepts. A higher value gives ERROR.

Record 2 Highest &N
0 9
4 10
8, 12 16
16, 31 39

Thus a Courier with no x2 bit gives ERROR for an x2 speed, for example &N39.

4.3 Calls

Supervisor 7.3.14 called D-Modem's courier_peer (AT+MS=X2) with tools/probe_v90modem_closed_loop.py:

Record 2 Result
31 CONNECT 49333/ARQ/x2/LAPM/V42BIS
15 The Courier sent no x2 marker. D-Modem went to V.34. The V.34 start-up failed (a known limit of the emulator).

Thus, in 7.3.14, record 2 bit 5 controls x2 in the call, not only the text of ATI7.

5. Who can write the record

Build ATC8= (after ATGLK2N) Remote (LAPM UI type 0a)
6.x Only when the record is not valid No handler
7.1.4 Only when the record is not valid Yes, with no permission bit
7.3.14 and later Only when the record is not valid Yes, when S30 bit 0 is set

In 6.5.4, the record decoder (ec59) has these callers only: the power-on code, ATY14 (7f6e) and the ATC handler (ec21). Its LAPM code accepts UI frames of type 08 and of types 40 and 60, but not of type 0a. Thus the features of a 6.x Courier cannot be changed from the line. The ATC path cannot change a valid record. It is for a new board.

6. Results for the x2 upgrade host

  • The host has an effect on x2 only on supervisor 7.0 to 7.3.x. In 7.4.16 and later, x2 and V.90 are always on. A host call changes the record but not the modem.
  • A 6.x Courier must load 7.x first.
  • The host can also set bit 3 (Terbo) and bit 4 (V.FC and V.34) on all 7.x builds. These bits change ATI7 and the speed limit. Whether the DSP code of a board that was sold without these features can run them is not known.
  • Bit 1 (HST) has no effect on the examined board, because the hardware probe sets HST.
  • The effect of bit 2 (fax) was not found. The supervisor reads runtime bit 08 in about nine places (7.1.4), mostly together with hardware bit 40. These places were not traced.

7. Not examined

  • Boards with hardware byte bit 40 or 80 (models without HST).
  • The code that reads runtime bit 08 (fax).
  • A V.34 call. The emulator does not complete the V.34 start-up with D-Modem.