The I-modem left the engine about 115k times a call for one CBW (at
0xa7515) and 85k for a SETZ (at 0xa5e50), each a round trip through
Python. SETcc is done in the engine on the 386 profile (the 80186 still
refuses the 0x0f escape, as the reference does); CBW and CWD no longer
yield there, since the engine already stops for any register with its
upper half set, and with those zero the 16-bit forms write exactly what
the reference's full-register write does. New differential test for
SETcc on both profiles; the full x2 call is bit-identical, wall 30.2 s ->
28.4 s.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
courier_worker_poll (c5x_capi.cpp) does what interpreter_service,
fast_service and clock_x86_fast do for a service in which only the DSP,
the clocks and the DSP's frame edge move: the codec-frame, line-sample and
probe tests, the DSP step with the same debt and CPI arithmetic, and the
INT0 frame-edge entry. Python arms it at the start of the batch after each
service of its own when every test of Python-only state comes out the
fast way, with a deadline before a timer's max count (the 80186 timers
advance lazily, as every access to one does first), the board tick, typed
input or the end of the run; the fields come back whenever the engine
returns. End-of-interrupt writes logged in the batch are applied to the
in-service stack before the frame-edge decision and marked, so the replay
leaves the stack alone. A DSP message, the call TDM starting, the loader
loop changing or a DSP error hand the rest of the service back to Python
(resume codes 2 and 3). The engine lends the poll its guard bytes and the
batch's port and memory-mapped write logs; lamp writes that repeat the
latch no longer force a Python poll.
64% of services now run natively. The x2 call, a Bell 103 call and a V.34
dial are bit-identical; the x2 call goes from 37 s to 33.6 s wall time
(CPU 60.7 s -> 56.3 s). COURIER_WORKER_POLL=0 turns it off.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The native x86 engine logs writes to bytes whose guard has bit 64 and the
harness replays them in order before it next runs any Python, so the end-of-
interrupt write no longer takes the engine out of its loop. Fix the poll-exit
bookkeeping to look at whether a poll is installed rather than at how many
arguments the engine was given.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012FxMN2ECAudm1U2CeD998v
Share the interrupt controllers, PIT wrap state and service deadlines in a
ctypes PollState, serve the PIC ports and the poll tail natively, and enter
interrupts in the engine. Bit-identical; full call 169 s -> 155 s.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012FxMN2ECAudm1U2CeD998v
With a call up on the bearer line, the engine settles PCM frames, feeds the
DSP ahead and advances it at each poll boundary itself, calling Python only
when a timer falls due, a device is touched, or the line clock has a frame to
send. What the skipped polls would have done to the interrupt controller is
done before anything looks at it. Bit-identical on the full call.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012FxMN2ECAudm1U2CeD998v
- libcourier_c5x: an I-modem port model serving the data lanes' stores,
the 0x18/0x1a status reads and latch writes and the lane window reads
from the DSP's I/O cells, together with the same C5x advance the
harness runs on every access and service pass (with the same read
quantum). It stops, leaving needs_service set, wherever the harness has
to act - a finished PCM frame or a reply to offer - and ImodemDsp
.service_pending performs that work and continues in Python.
- ImodemDsp's ledger and mailbox scalars (dsp_instructions, cycle debt,
PCM cursor, host_pending, tx_ready, consumed, reply writes, lane bytes)
live in a shared ctypes struct that Python and the native model use in
place, so nothing is marshalled per access.
- Status reads advance the C5x only if 32 instructions have passed since
its last advance; the skipped time stays owed. Writes advance exactly.
- The x86 engine hands port models the harness's instruction count;
after-I/O refresh is limited to the mailbox's own ports.
- Single-call getters replace dict-building stats reads on hot paths.
The I-modem's complete state, including every I/O tally, is bit-identical
with the native model on and off (COURIER_NATIVE_IO=0 selects the Python
path). Paired x2 still connects at 53333 with both payloads intact; full
call 250 s -> 216 s. Adds tests for both native port models.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012FxMN2ECAudm1U2CeD998v
- x86 engine: serve the analogue board's live data-lane ports (command,
ack, window reads/stores) through a port model in libcourier_c5x, which
works directly on the DSP's I/O cells. Tallies and last-written values
are folded back into the machine's I/O accounting; anything the model
declines still goes to Python.
- Port 0x14 (front-panel latch / board latch) writes are batched and
replayed in order on both modems.
- C5x core: the per-instruction V.8 dispatch probe is a bitmap lookup
instead of a vector scan, and the first-execution tracker is per core.
These ran on every retired instruction.
- I-modem: slimmer per-access DSP advance chain; core PC read through a
tiny getter; faster advance_imodem result handling.
- LineLink: optional COURIER_LINE_WINDOW (frames in flight, default 1 =
unchanged) so the two modem processes can run ahead of each other by the
line's transit delay.
Paired x2 still connects at 53333 with both payloads intact; full call
350 s -> 250 s. Registers, instruction counts and I/O tallies match the
previous build on the 60M control.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012FxMN2ECAudm1U2CeD998v
- Analog bridge: run the C5x to its cycle target in one native call
(step_cycles) instead of looping step()+state(), which also skips IDLE
spans; read line_tx_writes/samples and the codec rate through small
native getters instead of building the full serial/codec state dicts;
reuse ctypes buffers on the per-chunk calls.
- Line exchange runs once a useful batch of codec samples has accumulated
(bounded skip, fallback timer credited), not on every service chunk.
- Resampler dot product uses math.sumprod when available.
- x86 native engine retires software INT itself for vectors the harness
marks (I-modem: all vectors), counting them per vector; null vectors and
guarded accesses still fall back to the Python hook.
- advance_timer avoids two 64-bit divisions in the common period-1 case.
- Build the C5x library with -fno-semantic-interposition so calls inside it
skip the PLT and can inline.
Paired x2 (53333) still connects with both payloads intact; the I-modem's
register, interrupt and instruction state is identical to before on the
60M-instruction control. Adds a native-vs-hook INT equivalence test and
updates the audio-rate test double for line_tx_writes().
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_012FxMN2ECAudm1U2CeD998v
Repair call-overlay acknowledgements and wire the six-word runtime data window with separate DSP holding registers. Correct C5x filter timing and x86 interrupt entry, expand pair probes and diagnostics, and retain regression tests and capture evidence.