Type into a connected session: 7E1 CONNECT, and the data-mode receiver

Nothing typed after CONNECT ever reached the firmware, so the &T1 loopback
could not be exercised at all. Two faults in the DTE path, one behind the
other.

The data-mode boundary was never detected. This DTE runs 7E1, so the result
code comes out as `8d 0a c3 cf 4e 4e c5 c3 d4 8d 0a` - CONNECT with an
even-parity bit in the eighth - and matching raw bytes against b"CONNECT"
missed it, because only the characters whose parity is even survive the
comparison. online_mode stayed False for the rest of a connected run. Compare
the seven data bits instead.

The receive gate then held the queue shut. Past CONNECT the command parser is
not in the path: the firmware installs its data-mode receiver in the same
callback cell, 4502 on this ROM, and the whitelist of command_idle /
command_collecting read that as "parser busy, discard" - the state the gate
exists to wait out between a command and its result. In data mode there is no
command to wait for, so let the byte through.

With both, `AT&N1&T1` followed by HELLO delivers all five bytes: the trace
shows rom-rx 48/45/4c/4c/4f against the data-mode callbacks and
serial_input_remaining reaches 0, where it stuck at 5 before.

Nothing comes back yet. There is no echo on the DTE, and the transmitted line
signal is identical with and without the typed bytes - line_tx_nonzero 203675
either way - so the firmware accepts the characters but they do not reach the
modulator. The receive side is unchanged: rx_consumed 0.

No regressions: the AT&N1&T1 report is identical field for field, CONNECT
included, except online_mode now reads True; a linked 302 pair is unchanged on
both sides.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
Cryan209andClaude Opus 5 committed 2026-09-16 19:31:33 +12:00
1 parent 2858e52d40
commit 32faa8eb3b
1 file changed
+14 -1
+14 -1
View File
@@ -751,7 +751,14 @@ class CourierMachine:
self.serial_truncated = True
# CONNECT is the DTE boundary: subsequent bytes are payload, not AT
# commands. The firmware still owns the transition unless forced.
if not self.online_mode and b"CONNECT" in bytes(self.serial[-10:]).upper():
#
# Compare the seven data bits. This DTE runs 7E1, so the result code
# arrives as `c3 cf 4e 4e c5 c3 d4` - CONNECT with an even-parity bit
# in the eighth - and matching raw bytes missed it on every character
# whose parity happened to be odd. The run stayed in command mode for
# ever after its own CONNECT.
recent = bytes(byte & 0x7F for byte in self.serial[-10:])
if not self.online_mode and b"CONNECT" in recent.upper():
self.online_mode = True
self.serial_trace.append("entered-data-mode")
if self.console is not None:
@@ -1691,6 +1698,12 @@ class CourierMachine:
and (
not self._rom_dte_opened
or self.uart.holding
# Past CONNECT the command parser is not in the path at
# all: the firmware has installed its data-mode
# receiver in the same cell (4502 on this ROM), which
# this test read as "still busy" and never typed
# another character into a connected session.
or self.online_mode
# Let the parser finish its command/result before
# starting the next queued byte. Its busy RX handler
# deliberately discards input during this interval.